Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticleAdult Brain

Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions

J. Fagundes, M.G. Longo, S.Y. Huang, B.R. Rosen, T. Witzel, K. Heberlein, R.G. Gonzalez, P. Schaefer and O. Rapalino
American Journal of Neuroradiology September 2017, 38 (9) 1689-1694; DOI: https://doi.org/10.3174/ajnr.A5293
J. Fagundes
aFrom the Clínica de Diagnóstico por Imagem (J.F.), Rio de Janeiro, Brazil
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J. Fagundes
M.G. Longo
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for M.G. Longo
S.Y. Huang
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S.Y. Huang
B.R. Rosen
cAthinoula A. Martinos Center for Biomedical Imaging (B.R.R., T.W.), Charlestown, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for B.R. Rosen
T. Witzel
cAthinoula A. Martinos Center for Biomedical Imaging (B.R.R., T.W.), Charlestown, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for T. Witzel
K. Heberlein
dSiemens Medical Solutions (K.H.), Malvern, Pennsylvania.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for K. Heberlein
R.G. Gonzalez
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for R.G. Gonzalez
P. Schaefer
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for P. Schaefer
O. Rapalino
bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for O. Rapalino
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Article Information

vol. 38 no. 9 1689-1694
DOI 
https://doi.org/10.3174/ajnr.A5293
PubMed 
28705816

Published By 
American Journal of Neuroradiology
Print ISSN 
0195-6108
Online ISSN 
1936-959X
History 
  • Received March 6, 2017
  • Accepted after revision May 12, 2017
  • Published online September 8, 2017.

Article Versions

  • Latest version (July 13, 2017 - 08:54).
  • You are viewing the most recent version of this article.
Copyright & Usage 
© 2017 by American Journal of Neuroradiology

Author Information

  1. J. Fagundesa,
  2. M.G. Longob,
  3. S.Y. Huangb,
  4. B.R. Rosenc,
  5. T. Witzelc,
  6. K. Heberleind,
  7. R.G. Gonzalezb,
  8. P. Schaeferb and
  9. O. Rapalinob
  1. aFrom the Clínica de Diagnóstico por Imagem (J.F.), Rio de Janeiro, Brazil
  2. bDepartment of Radiology (M.G.L., S.Y.H., R.G.G., P.S., O.R.), Massachusetts General Hospital, Boston, Massachusetts
  3. cAthinoula A. Martinos Center for Biomedical Imaging (B.R.R., T.W.), Charlestown, Massachusetts
  4. dSiemens Medical Solutions (K.H.), Malvern, Pennsylvania.
  1. Please address correspondence to Otto Rapalino, MD, Department of Radiology, Massachusetts General Hospital, 55 Fruit St, Boston, MA 02114-2622; e-mail: orapalino{at}mgh.harvard.edu.
View Full Text

Altmetrics

Cited By...

  • 16 Citations
  • 17 Citations
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Highly‐accelerated volumetric brain examination using optimized wave‐CAIPI encoding
    Daniel Polak, Stephen Cauley, Susie Y. Huang, Maria Gabriela Longo, John Conklin, Berkin Bilgic, Ned Ohringer, Esther Raithel, Peter Bachert, Lawrence L. Wald, Kawin Setsompop
    Journal of Magnetic Resonance Imaging 2019 50 3
  • Practical Considerations for Radiologists in Implementing a Patient-friendly MRI Experience
    Murat Alp Oztek, Christina L. Brunnquell, Michael N. Hoff, Daniel J. Boulter, Mahmud Mossa-Basha, Luke H. Beauchamp, David L. Haynor, Xuan V. Nguyen
    Topics in Magnetic Resonance Imaging 2020 29 4
  • Contrast-to-Dose Relationship of Gadopiclenol, an MRI Macrocyclic Gadolinium-based Contrast Agent, Compared with Gadoterate, Gadobenate, and Gadobutrol in a Rat Brain Tumor Model
    Philippe Robert, Véronique Vives, Anne-Laure Grindel, Stéphane Kremer, Guillaume Bierry, Gaelle Louin, Sébastien Ballet, Claire Corot
    Radiology 2020 294 1
  • Artificial intelligence in multiparametric magnetic resonance imaging: A review
    Cheng Li, Wen Li, Chenyang Liu, Hairong Zheng, Jing Cai, Shanshan Wang
    Medical Physics 2022 49 10
  • Diagnostic performance of a new multicontrast one‐minute full brain exam (EPIMix) in neuroradiology: A prospective study
    Anna F. Delgado, Annika Kits, Jessica Bystam, Magnus Kaijser, Mikael Skorpil, Tim Sprenger, Stefan Skare
    Journal of Magnetic Resonance Imaging 2019 50 6
  • Clinical feasibility of 1-min ultrafast brain MRI compared with routine brain MRI using synthetic MRI: a single center pilot study
    Kyeong Hwa Ryu, Dae Seob Choi, Hye Jin Baek, Soo Buem Cho, Ji Young Ha, Tae Byeong Kim, Moon Jung Hwang
    Journal of Neurology 2019 266 2
  • Spiral 3-Dimensional T1-Weighted Turbo Field Echo: Increased Speed for Magnetization-Prepared Gradient Echo Brain Magnetic Resonance Imaging
    Thomas Sartoretti, Elisabeth Sartoretti, Luuk van Smoorenburg, Árpád Schwenk, Manoj Mannil, Nicole Graf, Christoph A. Binkert, Michael Wyss, Sabine Sartoretti-Schefer
    Investigative Radiology 2020 55 12
  • Diagnostic equivalency of fast T2 and FLAIR sequences for pediatric brain MRI: a pilot study
    Camilo Jaimes, Edward Yang, Pauline Connaughton, Caroline D. Robson, Richard L. Robertson
    Pediatric Radiology 2020 50 4
  • Modern acceleration in musculoskeletal MRI: applications, implications, and challenges
    Jan Vosshenrich, Gregor Koerzdoerfer, Jan Fritz
    Skeletal Radiology 2024 53 9
  • Evaluation of the Aggregated Time Savings in Adopting Fast Brain MRI Techniques for Outpatient Brain MRI
    Min Lang, Samuel Cartmell, Azadeh Tabari, Daniel Briggs, Oleg Pianykh, John Kirsch, Stephen Cauley, Wei-Ching Lo, Seretha Risacher, Augusto Goncalves Filho, Marc D Succi, Otto Rapalino, Pamela Schaefer, John Conklin, Susie Y Huang
    Academic Radiology 2023 30 2
  • Qualitative and Quantitative Analysis of a Spiral Gradient Echo Sequence for Contrast-Enhanced Fat-Suppressed T1-Weighted Spine Magnetic Resonance Imaging
    Elisabeth Sartoretti, Thomas Sartoretti, Luuk van Smoorenburg, Sabine Sartoretti-Schefer, Michael Wyss, Christoph A. Binkert
    Investigative Radiology 2021 56 8
  • Clinical Evaluation of a 2-Minute Ultrafast Brain MR Protocol for Evaluation of Acute Pathology in the Emergency and Inpatient Settings
    Min Lang, Bryan Clifford, Wei-Ching Lo, Brooks P. Applewhite, Azadeh Tabari, Augusto Lio M. Goncalves Filho, Zahra Hosseini, Maria Gabriela Figueiro Longo, Stephen F. Cauley, Kawin Setsompop, Berkin Bilgic, Thorsten Feiweier, Michael H. Lev, Pamela W. Schaefer, Otto Rapalino, Susie Y. Huang, John Conklin
    American Journal of Neuroradiology 2024 45 4
  • Clinical Feasibility of Automated Brain Tissue and Myelin Volumetry of Normal Brian Using Synthetic Magnetic Resonance Imaging With Fast Imaging Protocol: A Single-Center Pilot Study
    Zuofeng Zheng, Jiafei Yang, Dongpo Zhang, Jun Ma, Hongxia Yin, Zhenchang Wang
    Journal of Computer Assisted Tomography 2023 47 1
  • Usefulness of Wave-CAIPI for Postcontrast 3D T1-SPACE in the Evaluation of Brain Metastases
    H.J. Baek, Y.J. Heo, D. Kim, S.Y. Yun, J.W. Baek, H.W. Jeong, H.J. Choo, J.Y. Lee, S.-I. Oh
    American Journal of Neuroradiology 2022 43 6
  • Clinical validation of Wave-CAIPI susceptibility-weighted imaging for routine brain MRI at 1.5 T
    John Conklin, Maria Gabriela Figueiro Longo, Azadeh Tabari, Augusto Lio Goncalves Filho, Wei Liu, Daniel Nicolas Splitthoff, Wei-Ching Lo, Stephen F. Cauley, Kawin Setsompop, Pamela W. Schaefer, John E. Kirsch, Otto Rapalino, Susie Y. Huang
    European Radiology 2022 32 10
  • Evaluation of an Ultra-Short MRI Protocol for Cerebral Staging Examinations in Melanoma Patients
    Sönke Peters, Friederike Gärtner, Friederike Austein, Fritz Wodarg, Olav Jansen, Johannes Hensler
    RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 2022 194 04
  • Optimized flow compensation for contrast-enhanced T1-weighted Wave-CAIPI 3D MPRAGE imaging of the brain
    Azadeh Tabari, Min Lang, Komal Awan, Wei Liu, Bryan Clifford, Wei-Ching Lo, Daniel Nicolas Splitthoff, Stephen Cauley, Otto Rapalino, Pamela Schaefer, Susie Y. Huang, John Conklin
    European Radiology Experimental 2023 7 1
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 38 (9)
American Journal of Neuroradiology
Vol. 38, Issue 9
1 Sep 2017
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
J. Fagundes, M.G. Longo, S.Y. Huang, B.R. Rosen, T. Witzel, K. Heberlein, R.G. Gonzalez, P. Schaefer, O. Rapalino
Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions
American Journal of Neuroradiology Sep 2017, 38 (9) 1689-1694; DOI: 10.3174/ajnr.A5293

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions
J. Fagundes, M.G. Longo, S.Y. Huang, B.R. Rosen, T. Witzel, K. Heberlein, R.G. Gonzalez, P. Schaefer, O. Rapalino
American Journal of Neuroradiology Sep 2017, 38 (9) 1689-1694; DOI: 10.3174/ajnr.A5293
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Clinical Evaluation of a 2-Minute Ultrafast Brain MR Protocol for Evaluation of Acute Pathology in the Emergency and Inpatient Settings
  • Usefulness of Wave-CAIPI for Postcontrast 3D T1-SPACE in the Evaluation of Brain Metastases
  • Crossref (17)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Highly‐accelerated volumetric brain examination using optimized wave‐CAIPI encoding
    Daniel Polak, Stephen Cauley, Susie Y. Huang, Maria Gabriela Longo, John Conklin, Berkin Bilgic, Ned Ohringer, Esther Raithel, Peter Bachert, Lawrence L. Wald, Kawin Setsompop
    Journal of Magnetic Resonance Imaging 2019 50 3
  • Practical Considerations for Radiologists in Implementing a Patient-friendly MRI Experience
    Murat Alp Oztek, Christina L. Brunnquell, Michael N. Hoff, Daniel J. Boulter, Mahmud Mossa-Basha, Luke H. Beauchamp, David L. Haynor, Xuan V. Nguyen
    Topics in Magnetic Resonance Imaging 2020 29 4
  • Contrast-to-Dose Relationship of Gadopiclenol, an MRI Macrocyclic Gadolinium-based Contrast Agent, Compared with Gadoterate, Gadobenate, and Gadobutrol in a Rat Brain Tumor Model
    Philippe Robert, Véronique Vives, Anne-Laure Grindel, Stéphane Kremer, Guillaume Bierry, Gaelle Louin, Sébastien Ballet, Claire Corot
    Radiology 2020 294 1
  • Artificial intelligence in multiparametric magnetic resonance imaging: A review
    Cheng Li, Wen Li, Chenyang Liu, Hairong Zheng, Jing Cai, Shanshan Wang
    Medical Physics 2022 49 10
  • Diagnostic performance of a new multicontrast one‐minute full brain exam (EPIMix) in neuroradiology: A prospective study
    Anna F. Delgado, Annika Kits, Jessica Bystam, Magnus Kaijser, Mikael Skorpil, Tim Sprenger, Stefan Skare
    Journal of Magnetic Resonance Imaging 2019 50 6
  • Clinical feasibility of 1-min ultrafast brain MRI compared with routine brain MRI using synthetic MRI: a single center pilot study
    Kyeong Hwa Ryu, Dae Seob Choi, Hye Jin Baek, Soo Buem Cho, Ji Young Ha, Tae Byeong Kim, Moon Jung Hwang
    Journal of Neurology 2019 266 2
  • Spiral 3-Dimensional T1-Weighted Turbo Field Echo: Increased Speed for Magnetization-Prepared Gradient Echo Brain Magnetic Resonance Imaging
    Thomas Sartoretti, Elisabeth Sartoretti, Luuk van Smoorenburg, Árpád Schwenk, Manoj Mannil, Nicole Graf, Christoph A. Binkert, Michael Wyss, Sabine Sartoretti-Schefer
    Investigative Radiology 2020 55 12
  • Diagnostic equivalency of fast T2 and FLAIR sequences for pediatric brain MRI: a pilot study
    Camilo Jaimes, Edward Yang, Pauline Connaughton, Caroline D. Robson, Richard L. Robertson
    Pediatric Radiology 2020 50 4
  • Modern acceleration in musculoskeletal MRI: applications, implications, and challenges
    Jan Vosshenrich, Gregor Koerzdoerfer, Jan Fritz
    Skeletal Radiology 2024 53 9
  • Evaluation of the Aggregated Time Savings in Adopting Fast Brain MRI Techniques for Outpatient Brain MRI
    Min Lang, Samuel Cartmell, Azadeh Tabari, Daniel Briggs, Oleg Pianykh, John Kirsch, Stephen Cauley, Wei-Ching Lo, Seretha Risacher, Augusto Goncalves Filho, Marc D Succi, Otto Rapalino, Pamela Schaefer, John Conklin, Susie Y Huang
    Academic Radiology 2023 30 2

More in this TOC Section

  • Diagnostic Neuroradiology of Monoclonal Antibodies
  • Clinical Outcomes After Chiari I Decompression
  • Segmentation of Brain Metastases with BLAST
Show more ADULT BRAIN

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire