Index by author
Brunelle, F.
- FELLOWS' JOURNAL CLUBPediatric NeuroimagingYou have accessIncidental Brain MRI Findings in Children: A Systematic Review and Meta-AnalysisV. Dangouloff-Ros, C.-J. Roux, G. Boulouis, R. Levy, N. Nicolas, C. Lozach, D. Grevent, F. Brunelle, N. Boddaert and O. NaggaraAmerican Journal of Neuroradiology November 2019, 40 (11) 1818-1823; DOI: https://doi.org/10.3174/ajnr.A6281
Seven studies were included, reporting 5938 children (mean age, 11.3 ± 2.8 years). Incidental findings were present in 16.4% of healthy children, intracranial cysts being the most frequent (10.2%). Nonspecific white matter hyperintensities were reported in 1.9%, Chiari I malformation was found in 0.8%, and intracranial neoplasms were reported in 0.2%. In total, the prevalence of incidental findings needing follow-up was 2.6%. The prevalence of incidental findings is much more frequent in children than previously reported in adults, but clinically significant incidental findings were present in <1 in 38 children.
Campeau, N.G.
- FELLOWS' JOURNAL CLUBPatient SafetyOpen AccessEvaluation of Lower-Dose Spiral Head CT for Detection of Intracranial Findings Causing Neurologic DeficitsJ.G. Fletcher, D.R. DeLone, A.L. Kotsenas, N.G. Campeau, V.T. Lehman, L. Yu, S. Leng, D.R. Holmes, P.K. Edwards, M.P. Johnson, G.J. Michalak, R.E. Carter and C.H. McColloughAmerican Journal of Neuroradiology November 2019, 40 (11) 1855-1863; DOI: https://doi.org/10.3174/ajnr.A6251
Projection data from 83 patients undergoing unenhanced spiral head CT for suspected neurologic deficits were collected. A routine dose was obtained using 250 effective mAs and iterative reconstruction. Lower-dose configurations were reconstructed (25-effective mAs iterative reconstruction, 50-effective mAs filtered back-projection and iterative reconstruction, 100-effective mAs filtered back-projection and iterative reconstruction, 200-effective mAs filtered back-projection). Three neuroradiologists circled findings, indicating diagnosis, confidence, and image quality. The routine-dose jackknife alternative free-response receiver operating characteristic figure of merit was 0.87. Noninferiority was shown for 100-effective mAs iterative reconstruction and 200-effective mAs filtered back-projection, but not for100-effective mAs filtered back-projection. The authors conclude that substantial opportunity exists for dose reduction using spiral nonenhanced head CT and that the dose level might potentially be reduced to 40% of routine dose levels or a volume CT dose index of approximately 15mGy if slight decreases in performance are acceptable. The beneficial effect of iterative reconstrution was most pronounced at this 15-mGy dose level.
Capper, D.
- Pediatric NeuroimagingOpen AccessMRI Features of Histologically Diagnosed Supratentorial Primitive Neuroectodermal Tumors and Pineoblastomas in Correlation with Molecular Diagnoses and Outcomes: A Report from the Children's Oncology Group ACNS0332 TrialA. Jaju, E.I. Hwang, M. Kool, D. Capper, L. Chavez, S. Brabetz, C. Billups, Y. Li, M. Fouladi, R.J. Packer, S.M. Pfister, J.M. Olson and L.A. HeierAmerican Journal of Neuroradiology November 2019, 40 (11) 1796-1803; DOI: https://doi.org/10.3174/ajnr.A6253
Carter, R.E.
- FELLOWS' JOURNAL CLUBPatient SafetyOpen AccessEvaluation of Lower-Dose Spiral Head CT for Detection of Intracranial Findings Causing Neurologic DeficitsJ.G. Fletcher, D.R. DeLone, A.L. Kotsenas, N.G. Campeau, V.T. Lehman, L. Yu, S. Leng, D.R. Holmes, P.K. Edwards, M.P. Johnson, G.J. Michalak, R.E. Carter and C.H. McColloughAmerican Journal of Neuroradiology November 2019, 40 (11) 1855-1863; DOI: https://doi.org/10.3174/ajnr.A6251
Projection data from 83 patients undergoing unenhanced spiral head CT for suspected neurologic deficits were collected. A routine dose was obtained using 250 effective mAs and iterative reconstruction. Lower-dose configurations were reconstructed (25-effective mAs iterative reconstruction, 50-effective mAs filtered back-projection and iterative reconstruction, 100-effective mAs filtered back-projection and iterative reconstruction, 200-effective mAs filtered back-projection). Three neuroradiologists circled findings, indicating diagnosis, confidence, and image quality. The routine-dose jackknife alternative free-response receiver operating characteristic figure of merit was 0.87. Noninferiority was shown for 100-effective mAs iterative reconstruction and 200-effective mAs filtered back-projection, but not for100-effective mAs filtered back-projection. The authors conclude that substantial opportunity exists for dose reduction using spiral nonenhanced head CT and that the dose level might potentially be reduced to 40% of routine dose levels or a volume CT dose index of approximately 15mGy if slight decreases in performance are acceptable. The beneficial effect of iterative reconstrution was most pronounced at this 15-mGy dose level.
Cervenka, M.C.
- Adult BrainOpen AccessCerebral Ketones Detected by 3T MR Spectroscopy in Patients with High-Grade Glioma on an Atkins-Based DietA. Berrington, K.C. Schreck, B.J. Barron, L. Blair, D.D.M. Lin, A.L. Hartman, E. Kossoff, L. Easter, C.T. Whitlow, Y. Jung, F.-C. Hsu, M.C. Cervenka, J.O. Blakeley, P.B. Barker and R.E. StrowdAmerican Journal of Neuroradiology November 2019, 40 (11) 1908-1915; DOI: https://doi.org/10.3174/ajnr.A6287
Cha, S.
- Pediatric NeuroimagingOpen AccessDiffusion Characteristics of Pediatric Diffuse Midline Gliomas with Histone H3-K27M Mutation Using Apparent Diffusion Coefficient Histogram AnalysisM.S. Aboian, E. Tong, D.A. Solomon, C. Kline, A. Gautam, A. Vardapetyan, B. Tamrazi, Y. Li, C.D. Jordan, E. Felton, B. Weinberg, S. Braunstein, S. Mueller and S. ChaAmerican Journal of Neuroradiology November 2019, 40 (11) 1804-1810; DOI: https://doi.org/10.3174/ajnr.A6302
Chavez, L.
- Pediatric NeuroimagingOpen AccessMRI Features of Histologically Diagnosed Supratentorial Primitive Neuroectodermal Tumors and Pineoblastomas in Correlation with Molecular Diagnoses and Outcomes: A Report from the Children's Oncology Group ACNS0332 TrialA. Jaju, E.I. Hwang, M. Kool, D. Capper, L. Chavez, S. Brabetz, C. Billups, Y. Li, M. Fouladi, R.J. Packer, S.M. Pfister, J.M. Olson and L.A. HeierAmerican Journal of Neuroradiology November 2019, 40 (11) 1796-1803; DOI: https://doi.org/10.3174/ajnr.A6253
Chen, M.M.
- Head and Neck ImagingYou have accessDiagnostic Accuracy and Scope of Intraoperative Transoral Ultrasound and Transoral Ultrasound–Guided Fine-Needle Aspiration of Retropharyngeal MassesT.H. Vu, M. Kwon, S. Ahmed, M. Gule-Monroe, M.M. Chen, J. Sun, B.D. Fornage, J.M. Debnam and B. Edeiken-MonroeAmerican Journal of Neuroradiology November 2019, 40 (11) 1960-1964; DOI: https://doi.org/10.3174/ajnr.A6236
Chen, X.-J.
- Adult BrainYou have accessRole of 3D Pseudocontinuous Arterial Spin-Labeling Perfusion in the Diagnosis and Follow-Up in Patients with Herpes Simplex EncephalitisR. Li, P.-A. Shi, T.-F. Liu, Y. Li, Y. Wang, K. Wu, X.-J. Chen, H.-F. Xiao, Y.-L. Wang, L. Ma and X. LouAmerican Journal of Neuroradiology November 2019, 40 (11) 1901-1907; DOI: https://doi.org/10.3174/ajnr.A6279
Chivot, C.
- NeurointerventionYou have accessTransitioning to Transradial Access for Cerebral Aneurysm EmbolizationC. Chivot, R. Bouzerar and T. YzetAmerican Journal of Neuroradiology November 2019, 40 (11) 1947-1953; DOI: https://doi.org/10.3174/ajnr.A6234