Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticlePatient Safety

Effect of Tube Voltage on Image Quality in 64-Section Multidetector 3D CT Angiography: Evaluation with a Vascular Phantom with Superimposed Bone Skull Structures

Y. Murakami, S. Kakeda, K. Kamada, N. Ohnari, J. Nishimura, M. Ogawa, K. Otsubo, Y. Morishita and Y. Korogi
American Journal of Neuroradiology April 2010, 31 (4) 620-625; DOI: https://doi.org/10.3174/ajnr.A1871
Y. Murakami
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S. Kakeda
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
K. Kamada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
N. Ohnari
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J. Nishimura
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Ogawa
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
K. Otsubo
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Y. Morishita
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Y. Korogi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: Optimal tube voltage and tube current settings are not well established. The purpose of our study was to investigate the image quality on 3D CT angiograms of the brain at various kilovoltage settings by evaluating the depiction of simulated intracranial lesions by using a vascular phantom.

MATERIALS AND METHODS: An anthropomorphic vascular phantom with superimposed bone skull structures was designed to simulate various intracranial aneurysms with aneurysmal blebs. We performed CT angiography by using a 64-detector row CT scanner for various effective tube currents with 4 tube voltages of 80, 100, 120, and 135 kV(p). Simulated aneurysm enhancement and image noise were quantified; SNR and CNR were calculated. The depiction of the simulated aneurysms and blebs on 3D CT angiograms obtained with the volume-rendering technique was subjectively assessed. The effective dose was calculated on the basis of a CTDIw. The results of several protocols were compared by using the Student t test.

RESULTS: At identical doses levels (CTDIw), the mean SNR and CNR at 100 kV(p) were significantly higher than those at 80, 120, and 135 kV(p); and the mean qualitative image score at 100 kV(p) was significantly superior to those at 80 and 135 kV(p).

CONCLUSIONS: Our phantom study suggests that the tube voltage of 100 kV(p) is desirable for cerebral 3D CT angiograms, and the higher or lower kilovoltage settings may result in the degradation in diagnostic image quality.

Abbreviations

CNR
contrast-to-noise ratio
CTDIw
weighted CT dose index
kV(p)
kilovolt (peak)
MDCT
multidetector row CT
ROI
region of interest
SNR
signal-to-noise ratio
  • Copyright © American Society of Neuroradiology
View Full Text
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 31 (4)
American Journal of Neuroradiology
Vol. 31, Issue 4
1 Apr 2010
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Effect of Tube Voltage on Image Quality in 64-Section Multidetector 3D CT Angiography: Evaluation with a Vascular Phantom with Superimposed Bone Skull Structures
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
Y. Murakami, S. Kakeda, K. Kamada, N. Ohnari, J. Nishimura, M. Ogawa, K. Otsubo, Y. Morishita, Y. Korogi
Effect of Tube Voltage on Image Quality in 64-Section Multidetector 3D CT Angiography: Evaluation with a Vascular Phantom with Superimposed Bone Skull Structures
American Journal of Neuroradiology Apr 2010, 31 (4) 620-625; DOI: 10.3174/ajnr.A1871

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Effect of Tube Voltage on Image Quality in 64-Section Multidetector 3D CT Angiography: Evaluation with a Vascular Phantom with Superimposed Bone Skull Structures
Y. Murakami, S. Kakeda, K. Kamada, N. Ohnari, J. Nishimura, M. Ogawa, K. Otsubo, Y. Morishita, Y. Korogi
American Journal of Neuroradiology Apr 2010, 31 (4) 620-625; DOI: 10.3174/ajnr.A1871
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • Abbreviations
    • Materials and Methods
    • Results
    • Discussion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Lowering the Dose in Head CT Using Adaptive Statistical Iterative Reconstruction
  • Crossref (22)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Lowering the Dose in Head CT Using Adaptive Statistical Iterative Reconstruction
    K. Kilic, G. Erbas, M. Guryildirim, M. Arac, E. Ilgit, B. Coskun
    American Journal of Neuroradiology 2011 32 9
  • Digital Subtraction CT Angiography for Detection of Intracranial Aneurysms: Comparison with Three-dimensional Digital Subtraction Angiography
    Li Lu, Long Jiang Zhang, Colin S. Poon, Sheng Yong Wu, Chang Sheng Zhou, Song Luo, Mei Wang, Guang Ming Lu
    Radiology 2012 262 2
  • Preliminary report on virtual monochromatic spectral imaging with fast kVp switching dual energy head CT: comparable image quality to that of 120-kVp CT without increasing the radiation dose
    Kouhei Kamiya, Akira Kunimatsu, Harushi Mori, Jiro Sato, Masaaki Akahane, Takana Yamakawa, Kuni Ohtomo
    Japanese Journal of Radiology 2013 31 4
  • Imaging of Orthotopic Glioblastoma Xenografts in Mice Using a Clinical CT Scanner: Comparison with Micro-CT and Histology
    Stefanie Kirschner, Bettina Mürle, Manuela Felix, Anna Arns, Christoph Groden, Frederik Wenz, Andreas Hug, Gerhard Glatting, Martin Kramer, Frank A. Giordano, Marc A. Brockmann, Johannes Boltze
    PLOS ONE 2016 11 11
  • Dose reduction and image quality in CT angiography for cerebral aneurysm with various tube potentials and current settings
    K Imai, M Ikeda, C Kawaura, T Aoyama, Y Enchi, M Yamauchi
    The British Journal of Radiology 2012 85 1017
  • A low-radiation exposure protocol for 3D QCT of the spine
    O. Museyko, A. Heinemann, M. Krause, B. Wulff, M. Amling, K. Püschel, C. C. Glüer, W. Kalender, K. Engelke
    Osteoporosis International 2014 25 3
  • Reduced-dose CT protocol for the assessment of cerebral vasospasm
    N. Bricout, L. Estrade, F. Boustia, E. Kalsoum, J. P. Pruvo, X. Leclerc
    Neuroradiology 2015 57 12
  • Impact of organ-specific dose reduction on the image quality of head and neck CT angiography
    L. Schimmöller, R. S. Lanzman, P. Heusch, S. Dietrich, F. Miese, J. Aissa, T. A. Heusner, G. Antoch, P. Kröpil
    European Radiology 2013 23 6
  • Clinical validation of an AI-based motion correction reconstruction algorithm in cerebral CT
    Leilei Zhou, Hao Liu, Yi-Xuan Zou, Guozhi Zhang, Bin Su, Liyan Lu, Yu-Chen Chen, Xindao Yin, Hong-Bing Jiang
    European Radiology 2022 32 12
  • Toward accurate volumetry of brain aneurysms: Combination of an algorithm for automatic thresholding with a 3D eraser tool
    Vincent Costalat, Igor Lima Maldonado, Olivier Strauss, Alain Bonafé
    Journal of Neuroscience Methods 2011 198 2

More in this TOC Section

  • Safety of Intrathecal Gadobutrol in Various Doses
  • Impact of Kidney Function on CNS Gadolinium Deposition in Patients Receiving Repeated Doses of Gadobutrol
  • Contrast-Induced Acute Kidney Injury in Radiologic Management of Acute Ischemic Stroke in the Emergency Setting
Show more PATIENT SAFETY

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire