Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticleNeurointervention

Computerized Occlusion Rating: A Superior Predictor of Aneurysm Rebleeding for Ruptured Embolized Aneurysms

C. Sherif, A. Gruber, E. Schuster, E. Lahnsteiner, D. Gibson, H. Milavec, B. Feichter, M. Wiesender, C. Dorfer, M. Krawagna, A. Di Ieva, G. Bavinszki and E. Knosp
American Journal of Neuroradiology April 2012, DOI: https://doi.org/10.3174/ajnr.A3085
C. Sherif
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Gruber
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
E. Schuster
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
E. Lahnsteiner
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D. Gibson
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H. Milavec
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
B. Feichter
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Wiesender
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C. Dorfer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Krawagna
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Di Ieva
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
G. Bavinszki
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
E. Knosp
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: The initial angiographic occlusion rate is the strongest predictor of later rebleeding in previously ruptured coil-embolized cerebral aneurysms. Angiographic estimations of aneurysmal occlusion rates are, however, subjective in nature and confounded by methodologic problems. COR has been developed, and its superiority has been experimentally established to overcome subjective bias. The purpose of this study was to assess the clinical value of COR as a more objective predictor of aneurysm rebleeding when compared with SOR as described in the Raymond Classification.

MATERIALS AND METHODS: We applied COR in a consecutive series of 249 patients. Two DSA projections were selected independently by 2 blinded investigators. In cases of disagreement on the selected projections, a consensus decision was obtained. SOR were determined by 2 independent observers according to the Raymond classification. COR was measured by 2 blinded investigators. Interobserver variations were determined for SOR and COR. COR results were compared with SOR results and stratified as 100%, 99.9%–90%, 89.9%–70%, and <70% occlusion. SOR and COR were evaluated as predictors for aneurysm rebleeding.

RESULTS: Seven aneurysms rebled (2.8%; follow-up, 59 ± 35 months). In 20.9% of all cases, DSA selection was performed by consensus evaluations. Interobserver variations were statistically significant for SOR (P = .0030) but not for COR (P = .3517). Compared with COR, SOR overestimated the degree of aneurysmal occlusion in 81.9% of all cases. Only COR predicted rebleeding (P = .0162).

CONCLUSIONS: Unacceptable interobserver variations were shown for the standard SOR estimations. COR substantially reduced the impact of subjective bias. COR may, therefore, serve as an easily applicable more objective predictor of aneurysm rerupture. The remaining bias of COR, caused by 2D image analysis, may be overcome by use of direct 3D measurements.

Abbreviations

CARAT
Cerebral Aneurysm Rerupture After Treatment
COR
computerized occlusion rating
GOS
Glasgow Outcome Score
NS
not significant
OR
odds ratio
SOR
subjective occlusion rates
  • © 2012 American Society of Neuroradiology
Next
Back to top
Advertisement
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Computerized Occlusion Rating: A Superior Predictor of Aneurysm Rebleeding for Ruptured Embolized Aneurysms
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
C. Sherif, A. Gruber, E. Schuster, E. Lahnsteiner, D. Gibson, H. Milavec, B. Feichter, M. Wiesender, C. Dorfer, M. Krawagna, A. Di Ieva, G. Bavinszki, E. Knosp
Computerized Occlusion Rating: A Superior Predictor of Aneurysm Rebleeding for Ruptured Embolized Aneurysms
American Journal of Neuroradiology Apr 2012, DOI: 10.3174/ajnr.A3085

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Computerized Occlusion Rating: A Superior Predictor of Aneurysm Rebleeding for Ruptured Embolized Aneurysms
C. Sherif, A. Gruber, E. Schuster, E. Lahnsteiner, D. Gibson, H. Milavec, B. Feichter, M. Wiesender, C. Dorfer, M. Krawagna, A. Di Ieva, G. Bavinszki, E. Knosp
American Journal of Neuroradiology Apr 2012, DOI: 10.3174/ajnr.A3085
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
  • Info & Metrics
  • Responses
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Computerized Angiographic Occlusion Rating for Ruptured Clipped Aneurysms is Superior to Subjective Occlusion Rating
  • An update to the Raymond-Roy Occlusion Classification of intracranial aneurysms treated with coil embolization
  • Is long-term follow-up of adequately coil-occluded ruptured cerebral aneurysms always necessary? A single-center study of recurrences after endovascular treatment
  • Crossref (11)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • An update to the Raymond–Roy Occlusion Classification of intracranial aneurysms treated with coil embolization
    Justin R Mascitelli, Henry Moyle, Eric K Oermann, Maritsa F Polykarpou, Aanand A Patel, Amish H Doshi, Yakov Gologorsky, Joshua B Bederson, Aman B Patel
    Journal of NeuroInterventional Surgery 2015 7 7
  • Predictors of treatment failure following coil embolization of intracranial aneurysms
    Justin R. Mascitelli, Eric K. Oermann, Reade A. De Leacy, Henry Moyle, J. Mocco, Aman B. Patel
    Journal of Clinical Neuroscience 2015 22 8
  • Is long-term follow-up of adequately coil-occluded ruptured cerebral aneurysms always necessary? A single-center study of recurrences after endovascular treatment
    Alex M Mortimer, Hannah Marsh, Katherine Klimczak, Dhiraj Joshi, Helena Barton, Richard J Nelson, Marcus D Bradley, Shelley A Renowden
    Journal of NeuroInterventional Surgery 2015 7 5
  • Factors associated with rerupture of intracranial aneurysms after endovascular treatment: A retrospective review of 11 years experience at a single institution and review of the literature
    A.C. White, C.D. Roark, D.E. Case, D.A. Kumpe, J. Seinfeld
    Journal of Clinical Neuroscience 2017 44
  • Very large and giant microsurgical bifurcation aneurysms in rabbits: Proof of feasibility and comparability using computational fluid dynamics and biomechanical testing
    Camillo Sherif, Erwin Herbich, Roberto Plasenzotti, Helga Bergmeister, Ursula Windberger, Georg Mach, Gerhard Sommer, Gerhard A. Holzapfel, Thomas Haider, Martin Krssak, Guenther Kleinpeter
    Journal of Neuroscience Methods 2016 268
  • Management of recurrent aneurysms following endovascular therapy
    Kevin S. Chen, Thomas J. Wilson, William R. Stetler, Matthew C. Davis, David A. Giles, Elyne N. Kahn, Neeraj Chaudhary, Joseph J. Gemmete, B. Gregory Thompson, Aditya S. Pandey
    Journal of Clinical Neuroscience 2015 22 12
  • Computerized Angiographic Occlusion Rating for Ruptured Clipped Aneurysms is Superior to Subjective Occlusion Rating
    A.R. Al-Schameri, G. Baltsavias, P. Winkler, M. Lunzer, M. Kral, L. Machegger, F. Weymayr, S. Emich, C. Sherif, B. Richling
    American Journal of Neuroradiology 2015 36 9
  • Cerebral Vasospasm: Neurovascular Events After Subarachnoid Hemorrhage
    Helena Milavec, Andreas Gruber, Ernst Schuster, Eva Lahnsteiner, Christian Dorfer, Maximilian Krawagna, Engelbert Knosp, Camillo Sherif
    2013 115
  • Experimental Broad-Based Curved Sidewall Aneurysms in Rabbits Mimicking Human Carotid Siphon Aneurysms: Proof of Feasibility and Comparability Using Computational Fluid Dynamics
    Branko Popadic, Florian Scheichel, Cornelia Pangratz-Daller, Roberto Plasenzotti, Helga Bergmeister, Thomas Haider, Georg Mach, Martin Krssak, Camillo Sherif
    World Neurosurgery 2024 190
  • Intracranial Aneurysms
    Andrew C. White, Nicolas K. Khattar, Zaid S. Aljuboori, Jeffrey C. Obiora, Robert F. James
    2018

More in this TOC Section

  • Guided vs Conventional Angiography Systems
  • Rescue Reentry in Carotid Near-Occlusion
  • Contour Neurovascular System: Five Year Follow Up
Show more NEUROINTERVENTION

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire