Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

LetterLETTER

Do Prior Iodine Contrast Injections Affect Cerebral Blood Flow Measurement on CT Perfusion Studies of Patients with Large-Vessel Occlusions?

S.A. Amukotuwa, R. Bammer and S. Dehkharghani
American Journal of Neuroradiology August 2021, 42 (8) E56-E57; DOI: https://doi.org/10.3174/ajnr.A7139
S.A. Amukotuwa
aMonash Health ImagingMonash HealthMelbourne, AustraliaMonash UniversityClayton, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S.A. Amukotuwa
R. Bammer
bDepartment of Radiology, Royal Melbourne HospitalUniversity of MelbourneMelbourne, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for R. Bammer
S. Dehkharghani
cDepartments of Radiology and NeurologyNYU LangoneNew York, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S. Dehkharghani
  • Article
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

We read with great interest the recent study by Copelan et al1 in which the authors concluded that recent administration (< 8 hours) of iodinated contrast renders infarct estimations inaccurate using a commercial CTP processing software. We believe that the conclusions suffer from unassessed confounders and misinterpretations deserving of clarification for the prospective reader.

First, the small cohort (n = 38) differs not only in the use of iodine, but also in presentation time and infarct size. The transfer patient group arrived approximately 3.2 hours later than the direct presenters. In our experience, this delay increases the likelihood of distal clot migration (eg, from the ICA terminus to the M1 or M2 segment), which may explain the reported core underestimation using CBF. It is unclear whether this confounder was excluded after comparison of the emergent large-vessel occlusion location on each patient's baseline and post-transfer CTAs.

Second, both core under- and overestimations are well-described limitations of CTP that are inherent to using perfusion as a surrogate of the core.2 As shown in Fig 7,1 the authors compared a delay-insensitive CTP processing method (RApid processing of PerfusIon and Diffusion [RAPID; iSchemaView]) with a delay-compensated (but not delay-insensitive) parametric CTP processing method (Advanced-Visualization Workstation; GE Healthcare). The apparent CBF reduction on the parametric deconvolution methods is not easily disambiguated from artifactual changes arising from delay-estimation and compensation errors between the arterial input function and the tissue. Prior studies have shown that CBF observed with delay-compensated deconvolution methods can be underestimated by as much as 40% for delays of 5 seconds.2

Third, CTP maps are derived from dynamic attenuation changes caused by the iodine bolus, relative to the prebolus baseline attenuation values. Provided that a reliable prebolus baseline attenuation measurement is obtained, any attenuation offset caused by persistent intravascular or extravascular tissue iodine (from preceding injections) is negligible. It is unclear if the authors' CTP acquisitions had an adequate baseline measurement. The authors also acquired their CTP in 2 sequential slabs, each with a separate bolus injection, to achieve the desired 80-mm coverage. This means that the second CTP slab is, by definition, a postcontrast scan in both patient groups. Thus, any confounding effects from prior iodine administration should be observed in the second CTP slab in both groups. However, when allowing at least 90 seconds between the 2 CTP acquisitions, we have not encountered such issues in our experience with either dual slab protocols or cases in which the CTA is acquired before the CTP. If leakage is the culprit (either first pass or at a steady-state from an earlier injection for the CTP or the outside CTA study), then this would affect CBV and, to a much lesser extent, CBF. Although the authors reference contrast leakage as a potential explanation for core underestimation, they did not report on whether, or to what extent, patients demonstrated contrast staining on their pre- and postcontrast head CTs.

Last, the authors state that “rather than delay the reporting of such a clinically relevant pitfall to augment our sample size, we thought it pertinent to alert our […] colleagues to our finding.” While the effort to bring urgent findings to the attention of the broader scientific community is laudable, doing so at the expense of scientific rigor is fraught with danger. On the basis of the reported number of cases, we are uncertain whether meaningful conclusions can be drawn regarding the association between CBF-derived core and the robustness of collaterals. Specifically, only 2 and 3 cases with “poor collaterals” were reported in the iodine and noniodine groups, respectively, while “intermediate collaterals” were reported only in 6 and 3 cases, respectively. Moreover, the initial power analysis was based on a 50% core overestimation, not underestimation. Therefore, we are concerned for the potential conflation of correlation with causality.

In summary, we thank Copelan et al1 for sharing their findings and we agree with their conclusion that CBF can underestimate (or overestimate) core, and critically, that one should always cross-reference CTP with an unenhanced CT. We believe, however, that the authors' conclusions are excessively extrapolated and potentially without attention to well-recognized confounders. Several potential sources of bias may have had further influences upon the results, including the tendency to promote underestimation of the CBF core. Multiple prior studies, including post hoc analyses in large, prospectively collected cohorts and real-world populations with much larger numbers of patients, have documented accurate core estimations using the tested software, which included “transfer cases” with prior contrast.3,4

References

  1. 1.↵
    1. Copelan AZ,
    2. Smith ER,
    3. Drocton GT, et al
    . Recent administration of iodinated contrast renders core infarct estimation inaccurate using RAPID software. AJNR Am J Neuroradiol 2020;41:2235–42 doi:10.3174/ajnr.A6908 pmid:33214184
    Abstract/FREE Full Text
  2. 2.↵
    1. Kudo K,
    2. Christensen S,
    3. Sasaki M, et al
    . Accuracy and reliability assessment of CT and MR perfusion analysis software using a digital phantom. Radiology 2013;267:201–11 doi:10.1148/radiol.12112618 pmid:23220899
    CrossRefPubMed
  3. 3.↵
    1. Sarraj A,
    2. Hassan AE,
    3. Savitz S, et al
    . Outcomes of endovascular thrombectomy vs medical management alone in patients with large ischemic cores: a secondary analysis of the optimizing patient's selection for endovascular treatment in acute ischemic stroke (SELECT) study. JAMA Neurol 2019;76:1147–56 doi:10.1001/jamaneurol.2019.2109 pmid:31355873
    CrossRefPubMed
  4. 4.↵
    1. Dehkharghani S,
    2. Bammer R,
    3. Straka M, et al
    . Performance and predictive value of a user-independent platform for CT perfusion analysis: threshold-derived automated systems outperform examiner-driven approaches in outcome prediction of acute ischemic stroke. AJNR Am J Neuroradiol 2015;36:1419–25 doi:10.3174/ajnr.A4363 pmid:25999410
    Abstract/FREE Full Text
  • © 2021 by American Journal of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 42 (8)
American Journal of Neuroradiology
Vol. 42, Issue 8
1 Aug 2021
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Do Prior Iodine Contrast Injections Affect Cerebral Blood Flow Measurement on CT Perfusion Studies of Patients with Large-Vessel Occlusions?
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
S.A. Amukotuwa, R. Bammer, S. Dehkharghani
Do Prior Iodine Contrast Injections Affect Cerebral Blood Flow Measurement on CT Perfusion Studies of Patients with Large-Vessel Occlusions?
American Journal of Neuroradiology Aug 2021, 42 (8) E56-E57; DOI: 10.3174/ajnr.A7139

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Do Prior Iodine Contrast Injections Affect Cerebral Blood Flow Measurement on CT Perfusion Studies of Patients with Large-Vessel Occlusions?
S.A. Amukotuwa, R. Bammer, S. Dehkharghani
American Journal of Neuroradiology Aug 2021, 42 (8) E56-E57; DOI: 10.3174/ajnr.A7139
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • References
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • Reply:
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Reply:
  • Brain AVM’s Nidus: What if We Hadn’t Understood Anything?
  • Letter to the Editor regarding “Automated Volumetric Software in Dementia: Help or Hindrance to the Neuroradiologist?”
Show more LETTERS

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire