Index by author
Dornbos, D.
- NeurointerventionOpen AccessThrombectomy with Conscious Sedation Compared with General Anesthesia: A DEFUSE 3 AnalysisC.J. Powers, D. Dornbos, M. Mlynash, D. Gulati, M. Torbey, S.M. Nimjee, M.G. Lansberg, G.W. Albers and M.P. MarksAmerican Journal of Neuroradiology June 2019, 40 (6) 1001-1005; DOI: https://doi.org/10.3174/ajnr.A6059
Eisenmenger, L.
- FELLOWS' JOURNAL CLUBAdult BrainOpen AccessSurveillance of Unruptured Intracranial Saccular Aneurysms Using Noncontrast 3D-Black-Blood MRI: Comparison of 3D-TOF and Contrast-Enhanced MRA with 3D-DSAC. Zhu, X. Wang, L. Eisenmenger, B. Tian, Q. Liu, A.J. Degnan, C. Hess, D. Saloner and J. LuAmerican Journal of Neuroradiology June 2019, 40 (6) 960-966; DOI: https://doi.org/10.3174/ajnr.A6080
Sixty-four patients with 68 saccular unruptured intracranial aneurysms were recruited. Patients underwent 3T MR imaging with 3D-TOF-MRA, 3D black-blood MR imaging, and contrast-enhanced MRA, and they underwent 3D rotational angiography within 2 weeks. The neck, width, and height of the unruptured intracranial aneurysms were measured by 2 radiologists independently on 3D rotational angiography and 3 MR imaging sequences. 3D black-blood MR imaging demonstrates the best agreement with DSA, with the smallest limits of agreement and measurement error. 3D-TOF-MRA had the largest limits of agreement and measurement error. The authors conclude that 3D black-blood MR imaging achieves better accuracy for aneurysm size measurements compared with 3D-TOF, using 3D rotational angiography as a criterion standard.
Elgendy, Azza
- You have accessPerspectivesAzza ElgendyAmerican Journal of Neuroradiology June 2019, 40 (6) 927; DOI: https://doi.org/10.3174/ajnr.P0066
Ellingson, B.M.
- Adult BrainOpen AccessAssociation between Tumor Acidity and Hypervascularity in Human Gliomas Using pH-Weighted Amine Chemical Exchange Saturation Transfer Echo-Planar Imaging and Dynamic Susceptibility Contrast Perfusion MRI at 3TY.-L. Wang, J. Yao, A. Chakhoyan, C. Raymond, N. Salamon, L.M. Liau, P.L. Nghiemphu, A. Lai, W.B. Pope, N. Nguyen, M. Ji, T.F. Cloughesy and B.M. EllingsonAmerican Journal of Neuroradiology June 2019, 40 (6) 979-986; DOI: https://doi.org/10.3174/ajnr.A6063
Elmokadem, A.H.
- Adult BrainOpen AccessDiagnostic Accuracy of High-Resolution Black-Blood MRI in the Evaluation of Intracranial Large-Vessel Arterial OcclusionsA.S. Al-Smadi, R.N. Abdalla, A.H. Elmokadem, A. Shaibani, M.C. Hurley, M.B. Potts, B.S. Jahromi, T.J. Carroll and S.A. AnsariAmerican Journal of Neuroradiology June 2019, 40 (6) 954-959; DOI: https://doi.org/10.3174/ajnr.A6065
Fan, G.
- SpineOpen AccessDeep Learning–Based Automatic Segmentation of Lumbosacral Nerves on CT for Spinal Intervention: A Translational StudyG. Fan, H. Liu, Z. Wu, Y. Li, C. Feng, D. Wang, J. Luo, W.M. Wells and S. HeAmerican Journal of Neuroradiology June 2019, 40 (6) 1074-1081; DOI: https://doi.org/10.3174/ajnr.A6070
Fatterpekar, G.M.
- Head & NeckYou have accessDynamic Contrast-Enhanced MRI to Differentiate Parotid Neoplasms Using Golden-Angle Radial Sparse Parallel ImagingJ.L. Mogen, K.T. Block, N.K. Bansal, J.T. Patrie, S. Mukherjee, E. Zan, M. Hagiwara, G.M. Fatterpekar and S.H. PatelAmerican Journal of Neuroradiology June 2019, 40 (6) 1029-1036; DOI: https://doi.org/10.3174/ajnr.A6055
Feng, C.
- SpineOpen AccessDeep Learning–Based Automatic Segmentation of Lumbosacral Nerves on CT for Spinal Intervention: A Translational StudyG. Fan, H. Liu, Z. Wu, Y. Li, C. Feng, D. Wang, J. Luo, W.M. Wells and S. HeAmerican Journal of Neuroradiology June 2019, 40 (6) 1074-1081; DOI: https://doi.org/10.3174/ajnr.A6070
Fischer, N.
- FELLOWS' JOURNAL CLUBHead & NeckYou have accessReadout-Segmented Echo-Planar DWI for the Detection of Cholesteatomas: Correlation with Surgical ValidationN. Fischer, V.H. Schartinger, D. Dejaco, J. Schmutzhard, H. Riechelmann, M. Plaikner and B. HenningerAmerican Journal of Neuroradiology June 2019, 40 (6) 1055-1059; DOI: https://doi.org/10.3174/ajnr.A6079
Readout-segmented echo-planar (RESOLVE)-DWI is a new alternative technique for obtaining DWI with high quality, delivering sharp images at high spatial resolution and reduced slice thickness. Fifty patients with chronic otitis media who underwent MR imaging before an operation of the middle ear were included. The MR imaging protocol consisted of axial and coronal readout-segmented echo-planar DWI with b-values of 0 and 1000 s/mm2 and 3-mm slice thickness. The readout segmented echo-planar diffusion-weighted images were fused with standard T2-weighted sequences for better anatomic assignment. Readout-segmented echo-planar DWI detected 22 of the 25 cases of surgically proved cholesteatoma. It has an accuracy of 92%, a sensitivity of 88%, a specificity of 96%, a positive predictive value of 96%, and a negativepredictive value of 89%. Readout-segmented echo-planar DWI is a promising and reliable MR imaging sequence for the detection and exclusion of cholesteatoma.
Flemming, K.D.
- Adult BrainOpen AccessBaseline and Evolutionary Radiologic Features in Sporadic, Hemorrhagic Brain Cavernous MalformationsK.D. Flemming, S. Kumar, G. Lanzino and W. BrinjikjiAmerican Journal of Neuroradiology June 2019, 40 (6) 967-972; DOI: https://doi.org/10.3174/ajnr.A6076