Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

ReplyLetter

Reply:

A.C. Coan and F. Cendes
American Journal of Neuroradiology October 2013, 34 (10) E116; DOI: https://doi.org/10.3174/ajnr.A3751
A.C. Coan
aNeuroimaging Laboratory, Department of Neurology State University of Campinas Campinas, São Paulo, Brazil
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
F. Cendes
aNeuroimaging Laboratory, Department of Neurology State University of Campinas Campinas, São Paulo, Brazil
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Pardoe and Jackson have commented on our recent article1 in which we demonstrated that automated hippocampal volumetry in 3T MR images can improve the detection of signs of hippocampal sclerosis. They discuss in their letter that consistent data in the literature have demonstrated that manual hippocampal segmentation has a higher sensitivity and specificity than the current automated methods.2 Our study did not address this issue directly because we did not compare the results with manual volumetry. Nevertheless, we believe this is a very important point that needs further discussion.

Taking this issue on a purely conceptual basis, we believe it is logical to assume that automatic MR imaging segmentation will never be superior to evaluation by expert professionals for clinical diagnosis. Therefore, any automatic segmentation would be an additional tool for the imaging diagnosis and never a substitute. As for the sensitivity and specificity of manual vs automatic segmentation, the question is more complex, simply because it will depend on 3 main factors: 1) level of expertise of the professional drawing the boundaries of the hippocampi, 2) the program used for automatic segmentation, and 3) the quality of the MR imaging scan. Because these 3 factors vary significantly among centers, and also because of the constant improvement in software and hardware for imaging acquisition and postprocessing, it is hard to compare different studies.

Our group has extensive experience with manual hippocampal volumetry, with a personal contribution to the validation of the volumetry protocol that is still commonly used.3,4 An important earlier study showed that qualitative visual analysis correctly identified hippocampal sclerosis in most patients (41/44; 93%) and that hippocampal volumetry provided localization in an additional small number of patients (43/44; 97%).5 Since then, imaging scanners and protocols have improved significantly and, thus, the accuracy of visual analyses.

However, although it has been known for more than 20 years that manual hippocampal volumetry can improve visual analysis in the detection of hippocampal sclerosis, why is it still not widely used as a clinical tool? In our opinion, there are 2 main reasons for this: 1) manual volumetry is very time consuming and not practical for radiology clinics, and 2) it is operator dependent. For experienced operators, manual hippocampal volumetry shows very reliable results, but for those without considerable experience, the results vary and the interrater agreement may be very poor.

Another important point is the possible difference in accuracy between the manual vs the automated method to detect hippocampal abnormalities in severe vs subtle hippocampal sclerosis. Although visual analyses with an adequate MR imaging protocol correctly identify signs of hippocampal sclerosis in most patients,1,5 the accuracy of the volumetry tool should also be measured to detect subtle cases in the clinical context, where it would be most useful, and not necessarily in cases where one can detect easily gross asymmetries by visual analysis by using different (T1, T2, FLAIR) images with appropriate acquisition (high-resolution, thin coronal cuts perpendicular to the hippocampi). Clinicians need a validated practical tool for these difficult cases, not for those with clear-cut MRI finding of hippocampal sclerosis (we are not talking here about segmentation for research purposes). This issue has not yet been properly addressed.

Neuroimaging has transformed evaluation of epilepsies that are resistant to antiepileptic drugs. A relevant challenge is to be able to transform a negative MR image into an MR image with evidence of focal abnormality, which can substantially increase the odds of successful surgical treatment of seizures in a given patient. In our study, we demonstrated that hippocampal volumetry and signal quantification are still useful for increasing the detection of MR imaging–positive temporal lobe epilepsy, even in patients who had normal MR imaging results by visual analyses.1 We strongly believe that hippocampal volumetry should be used in the presurgical evaluation of patients with antiepileptic drug–resistant epilepsy. But for that, volumetry must be practical, not time consuming, and free of human bias. More efforts should be made to improve automatic techniques, including improved sensitivity and specificity, to make this technique clinically widely available.

REFERENCES

  1. 1.↵
    1. Coan AC,
    2. Kubota B,
    3. Bergo FP,
    4. et al
    . 3T MRI quantification of hippocampal volume and signal in mesial temporal lobe epilepsy improves detection of hippocampal sclerosis. AJNR Am J Neuroradiol 2013 Jul 18 [Epub ahead of print]
  2. 2.↵
    1. Pardoe HR,
    2. Pell GS,
    3. Abbott DF,
    4. et al
    . Hippocampal volume assessment in temporal lobe epilepsy: how good is automated segmentation? Epilepsia 2009;50:2586–92
    CrossRefPubMed
  3. 3.↵
    1. Watson C,
    2. Cendes F,
    3. Fuerst D,
    4. et al
    . Specificity of volumetric magnetic resonance imaging in detecting hippocampal sclerosis. Arch Neurol 1997;54:67–73
    CrossRefPubMed
  4. 4.↵
    1. Cendes F,
    2. Andermann F,
    3. Gloor P,
    4. et al
    . MRI volumetric measurement of amygdala and hippocampus in temporal lobe epilepsy. Neurology 1993;43:719–25
    CrossRef
  5. 5.↵
    1. Kuzniecky RI,
    2. Bilir E,
    3. Gilliam F,
    4. et al
    . Multimodality MRI in mesial temporal sclerosis: relative sensitivity and specificity. Neurology 1997;49:774–78
    CrossRef
  • © 2013 by American Journal of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 34 (10)
American Journal of Neuroradiology
Vol. 34, Issue 10
1 Oct 2013
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Reply:
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
A.C. Coan, F. Cendes
Reply:
American Journal of Neuroradiology Oct 2013, 34 (10) E116; DOI: 10.3174/ajnr.A3751

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Reply:
A.C. Coan, F. Cendes
American Journal of Neuroradiology Oct 2013, 34 (10) E116; DOI: 10.3174/ajnr.A3751
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • REFERENCES
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • Manual Hippocampal Volumetry Is a Better Detector of Hippocampal Sclerosis than Current Automated Hippocampal Volumetric Methods
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Letter to the Editor regarding “Automated Volumetric Software in Dementia: Help or Hindrance to the Neuroradiologist?”
  • Reply:
  • Brain AVM’s Nidus: What if We Hadn’t Understood Anything?
Show more LETTERS

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire