Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticleSpine Imaging and Spine Image-Guided Interventions
Open Access

Restoration of Spinal Alignment and Disk Mechanics following Polyetheretherketone Wafer Kyphoplasty with StaXx FX

S.M. Renner, P.P. Tsitsopoulos, A.T. Dimitriadis, L.I. Voronov, R.M. Havey, G. Carandang, B. McIntosh, C. Carson, D. Ty, J.G. Ringelstein and A.G. Patwardhan
American Journal of Neuroradiology August 2011, 32 (7) 1295-1300; DOI: https://doi.org/10.3174/ajnr.A2484
S.M. Renner
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P.P. Tsitsopoulos
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A.T. Dimitriadis
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
L.I. Voronov
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R.M. Havey
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
G. Carandang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
B. McIntosh
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C. Carson
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D. Ty
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J.G. Ringelstein
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A.G. Patwardhan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: EPFs sustained during VCFs degrade the disk's ability to develop IDP under load. This inability to develop pressure in combination with residual kyphotic deformity increases the risk for adjacent vertebral fractures. We tested the hypothesis that StaXx FX reduces kyphosis and endplate deformity following vertebral compression fracture, restoring disk mechanics.

MATERIALS AND METHODS: Eight thoracolumbar, 5-vertebrae segments were tested. A void was selectively created in the middle vertebra. The specimens were compressed until EPF and to a grade I–II VCF. PEEK wafer kyphoplasty was then performed. The specimens were then tested in flexion-extension (±6 Nm) under 400-N preload intact, after EPF, VCF, and kyphoplasty. Endplate deformity, kyphosis, and IDP adjacent to the fractured body were measured.

RESULTS: Vertebral body height at the point of maximal endplate deformity decreased after EPF and VCF and was partially corrected after StaXx FX, remaining less than intact (P = .047). Anterior vertebral height decreased after VCF (P = .002) and was partially restored with StaXx FX, remaining less than intact (P = .015). Vertebral kyphosis increased after VCF (P < .001) and reduced after StaXx FX, remaining greater than intact (P = .03). EPF reduced IDP in the affected disk in compression-flexion loading (P < .001), which was restored after StaXx FX (P = 1.0). IDP in the unaffected disk did not change during testing (P > .3).

CONCLUSIONS: StaXx FX reduced endplate deformity and kyphosis, and significantly increased anterior height following VCF. Although height and kyphosis were not fully corrected, the disk's ability to pressurize under load was restored.

Abbreviations

EPF
endplate fracture
IDP
intradiskal pressure
PEEK
polyetherether-ketone
VCF
vertebral compression fracture
  • Copyright © American Society of Neuroradiology

Indicates open access to non-subscribers at www.ajnr.org

View Full Text
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 32 (7)
American Journal of Neuroradiology
Vol. 32, Issue 7
1 Aug 2011
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Restoration of Spinal Alignment and Disk Mechanics following Polyetheretherketone Wafer Kyphoplasty with StaXx FX
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
S.M. Renner, P.P. Tsitsopoulos, A.T. Dimitriadis, L.I. Voronov, R.M. Havey, G. Carandang, B. McIntosh, C. Carson, D. Ty, J.G. Ringelstein, A.G. Patwardhan
Restoration of Spinal Alignment and Disk Mechanics following Polyetheretherketone Wafer Kyphoplasty with StaXx FX
American Journal of Neuroradiology Aug 2011, 32 (7) 1295-1300; DOI: 10.3174/ajnr.A2484

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Restoration of Spinal Alignment and Disk Mechanics following Polyetheretherketone Wafer Kyphoplasty with StaXx FX
S.M. Renner, P.P. Tsitsopoulos, A.T. Dimitriadis, L.I. Voronov, R.M. Havey, G. Carandang, B. McIntosh, C. Carson, D. Ty, J.G. Ringelstein, A.G. Patwardhan
American Journal of Neuroradiology Aug 2011, 32 (7) 1295-1300; DOI: 10.3174/ajnr.A2484
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • Abbreviations
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Biomechanical Comparison of Robotically Applied Pure Moment, Ideal Follower Load, and Novel Trunk Weight Loading Protocols on L4-L5 Cadaveric Segments during Flexion-Extension
  • Crossref (10)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Kyphopasty and vertebroplasty
    S. Teyssédou, M. Saget, P. Pries
    Orthopaedics & Traumatology: Surgery & Research 2014 100 1
  • Radiologic study of disc behavior following compression fracture of the thoracolumbar hinge managed by kyphoplasty: A 52-case series
    S. Teyssédou, M. Saget, L.E. Gayet, P. Pries, C. Brèque, T. Vendeuvre
    Orthopaedics & Traumatology: Surgery & Research 2016 102 1
  • Analysis of intervertebral discs adjacent to thoracolumbar A3 fractures treated by percutaneous instrumentation and kyphoplasty
    Arnaud Collinet, Yann Philippe Charles, Yves Ntilikina, Nicolas Tuzin, Jean-Paul Steib
    Orthopaedics & Traumatology: Surgery & Research 2020 106 6
  • Innovative minimally invasive implants for osteoporosis vertebral compression fractures
    Yi Luo, Da-Mei Yang, Hong-Mei Yang, Di Wu, Feng-Ying Xie
    Frontiers in Medicine 2023 10
  • Robotic application of a dynamic resultant force vector using real-time load-control: Simulation of an ideal follower load on Cadaveric L4–L5 segments
    Charles R. Bennett, Brian P. Kelly
    Journal of Biomechanics 2013 46 12
  • Re-expansion of vertebral compression fractures in patients with multiple myeloma with percutaneous vertebroplasty using spinejack implants: a preliminary and retrospective study
    Claudio Pusceddu, Eliodoro Faiella, Daniele Derudas, Nicola Ballicu, Luca Melis, Stefano Zedda, Salvatore Marsico
    Frontiers in Surgery 2023 10
  • Treatment of an osteoporotic vertebral compression fracture with the StaXx FX system resulting in intrathoracic wafers: a serious complication
    L. W. van der Plaat, G. H. Bulstra, G. H. R. Albers, J. P. Eerenberg, H. M. van der Vis
    European Spine Journal 2012 21 S4
  • Analyse des disques adjacents à une fracture A3 de la charnière thoracolombaire traitée par kyphoplastie et ostéosynthèse percutanée
    Arnaud Collinet, Yann Philippe Charles, Yves Ntilikina, Nicolas Tuzin, Jean-Paul Steib
    Revue de Chirurgie Orthopédique et Traumatologique 2020 106 6
  • Conférences D&#039;enseignement 2013
    P. Pries
    2013
  • Étude radiologique du comportement discal après fracture en compression de la charnière thoracolombaire traitée par cyphoplastie : à propos d’une série de 52 cas
    S. Teyssédou, M. Saget, L.E. Gayet, P. Pries, C. Brèque, T. Vendeuvre
    Revue de Chirurgie Orthopédique et Traumatologique 2016 102 1

More in this TOC Section

  • Advanced Imaging of Type 2 Spinal CSF Leaks
  • Optimization of Photon Counting CT Myelography
  • Characteristics of SIH Type I Culprit Lesions
Show more Spine Imaging and Spine Image-Guided Interventions

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire