OtherResearch Perspectives
Dangerous Advances in Measurements from Digital Subtraction Angiography: When Is a Millimeter Not a Millimeter?
A.J. Fox, J. Millar, J. Raymond, J.C. Pryor, D. Roy, G.A. Tomlinson, J.P. McKay and A.J. Molyneux
American Journal of Neuroradiology March 2009, 30 (3) 459-461; DOI: https://doi.org/10.3174/ajnr.A1381
A.J. Fox
J. Millar
J. Raymond
J.C. Pryor
D. Roy
G.A. Tomlinson
J.P. McKay

References
- ↵Renowdena SA, Koumellisb P, Benesc V, et al. Retreatment of previously embolized cerebral aneurysms: the risk of further coil embolization does not negate the advantage of the initial embolization. AJNR Am J Neuroradiol 2008;29:1401–04
- Pelusoa JP, van Rooij WJ, Sluzewski M, et al. A new self-expandable nitinol stent for the treatment of wide-neck aneurysms: initial clinical experience. AJNR Am J Neuroradiol 2008;29:1405–08. Epub 2008 Apr 24
- Laytona KF, Hisea JH, Thackera IC. Recurrent intracranial stenosis induced by the Wingspan stent: comparison with balloon angioplasty alone in a single patient. AJNR Am J Neuroradiol 2008;29:1050–52
- ↵Tsumotoa T, Songa JK, Niimia Y, et al. Interval change in size of venous pouch canine bifurcation aneurysms over a 10-month period. AJNR Am J Neuroradiol 2008;29:1067–70
- ↵Forbes G, Fox AJ, Huston J, et al. Interobserver variability in angiographic measurement and morphologic characterization of intracranial aneurysms: a report from the International Study of Unruptured Aneurysms. AJNR Am J Neuroradiol 1996;17:1407–15
- ↵Bartlett ES, Walters TD, Symons SP, et al. Quantification of carotid stenosis on CT angiography. AJNR Am J Neuroradiol 2006;27:13–19
- ↵MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70–99%) or with mild (0–29%) carotid stenosis—European Carotid Surgery Trialists’ Collaborative Group. Lancet 1991;337:1235–43
- ↵Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis: North American Symptomatic Carotid Endarterectomy Trial Collaborators. N Engl J Med 1991;325:445–53
- ↵Fox AJ. How to measure carotid stenosis. Radiology 1993;186:316–18
- ↵Rothwell PM, Gibson RJ, Slattery J, et al. Equivalence of measurements of carotid stenosis: a comparison of three methods on 1001 angiograms. Stroke 1994;25:2435–39
- ↵Fox AJ, Eliasziw M, Rothwell PM, et al. Identification, prognosis, and management of patients with carotid artery near occlusion. AJNR Am J Neuroradiol 2005;26:2086–94
- ↵Wiebers DO, Whisnant JP, Huston J 3rd, et al. Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment. Lancet 2003;362:103–10
- ↵Fernandez Zubillaga A, Guglielmi G, Vinuela F, et al. Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results. AJNR Am J Neuroradiol 1994;15:815–20
- ↵Horton JA. Sizing rings: a simple technique for measuring intracranial lesions. AJNR Am J Neuroradiol 1995;16:1449–51
- Malek AM, Higashida RT, Halbach VV, et al. Patient presentation, angiographic features, and treatment of strangulation-induced bilateral dissection of the cervical internal carotid artery: report of three cases. J Neurosurg 2000;92:481–87
- Pride GL Jr, Horowitz MB, Purdy PD. Endovascular problem solving with intravascular stents. AJNR Am J Neuroradiol 2000;21:532–40
- ↵
- ↵Fahrig R, Holdsworth DW, Fox AJ, et al. Use of a C-arm system to generate true 3-D computed rotational angiograms: preliminary in vitro and in vivo results. AJNR Am J Neuroradiol 1997;18:1507–14
- ↵
In this issue
Advertisement
A.J. Fox, J. Millar, J. Raymond, J.C. Pryor, D. Roy, G.A. Tomlinson, J.P. McKay, A.J. Molyneux
Dangerous Advances in Measurements from Digital Subtraction Angiography: When Is a Millimeter Not a Millimeter?
American Journal of Neuroradiology Mar 2009, 30 (3) 459-461; DOI: 10.3174/ajnr.A1381
0 Responses
Jump to section
Related Articles
- No related articles found.
Cited By...
- Cerecyte Coil Trial: Angiographic Outcomes of a Prospective Randomized Trial Comparing Endovascular Coiling of Cerebral Aneurysms With Either Cerecyte or Bare Platinum Coils
- Reporting standards for angiographic evaluation and endovascular treatment of cerebral arteriovenous malformations
- Potent Risk Factor for Aneurysm Formation: Termination Aneurysms of the Anterior Communicating Artery and Detection of A1 Vessel Asymmetry by Flow Dilution
- Should Modeling Methodology Suppress Anatomic Excellence?
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles
Advertisement