Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

OtherSpine Imaging and Spine Image-Guided Interventions

Lower Cervical Nerve Root Block Using CT Fluoroscopy in Patients with Large Body Habitus: Another Benefit of the Swimmer's Position

W.S. Bartynski, D.S. Whitt, M.A. Sheetz, R.B. Jennings and W.E. Rothfus
American Journal of Neuroradiology April 2007, 28 (4) 706-708;
W.S. Bartynski
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D.S. Whitt
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M.A. Sheetz
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R.B. Jennings
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
W.E. Rothfus
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

SUMMARY: We describe a method of performing lower cervical nerve root block (CNRB) with CT fluoroscopy in patients with large body habitus using the swimmer's position. This approach reduces image noise with acceptable visualization of vital structures and improved foraminal/root access. Anticipated use of the swimmer's position coupled with minimally modified radiation exposure parameters can limit radiation dose to operator/patient and reduce procedure time to match that of CNRB using CT fluoroscopy in typical patients.

Cervical nerve root block/steroid injection (CNRB) is commonly performed with CT or CT fluoroscopy (CTF).1–3 This procedure can be challenging, in particular at lower cervical levels and in patients with a large body habitus (LBH) because of compromised image quality or limited trajectory options for foramen access because of the clavicle or shoulder. Poor visualization of critical structures, including the carotid artery, jugular vein, vertebral artery, and neural foramen, can occur.

The swimmer's position is traditionally used at the cervicothoracic junction in radiography/fluoroscopy and was recently advocated in the lower cervical spine for diagnostic CT.4 We encountered several patients with LBH and lower cervical radiculopathy in which we modified our standard CNRB technique using a swimmer's position for improved visualization and access to the lower cervical foramina.

We describe our experience with this technique modification along with CT phantom assessment of operator/patient radiation exposure when performing CNRB with CT fluoroscopy, in particular at higher CTF dose levels.

Technique

CNRB was requested in 9 patients (6 male, 3 female) with LBH and lower cervical radiculopathy (single root: 7; 2 roots: 2; C6: 5, C7: 5, C8: 1). Supine scout CT (120 kVp, 250 ± 50 mA, 20–25 cm FOV, 3-mm section thickness) was performed for level confirmation, foramen location, and trajectory determination, which demonstrated extensive beam-hardening artifacts obscuring the overlying vessels and target foramen. This suggested an unacceptable compromise in visualization by standard CTF, theoretically forcing higher exposure parameters.

As an alternative, patients were placed in the swimmer's position and scout CT was repeated. Critical blood vessels and the target foramen/root were more clearly identified and target access options improved (Fig 1). CNRB was performed in the swimmer's position using CTF and a 25-gauge spinal needle. Standard CTF spot images (range used in patients: 120–40 kVp, 50–100 mA, 20–25 cm FOV, 3-mm section thickness) were used to establish needle entry point and needle tip depth as it approached the target foramen/root. Vertebral tilt induced by the swimmer's position resulted in foramen obliquity, but the needle could easily be followed as it entered the foramen and approached the root (Fig 1G, -H). Safe needle tip location was confirmed by local contrast accumulation adjacent to the nerve root (0.2–0.3 mL of iohexol, 180 mg of I/mm3; GE Medical Products, Milwaukee, Wis) by CTF. Methylprednisolone acetate 80 mg and bupivacaine 0.25% (2 mL for single root; 3 mL for double root, dose divided) were injected with intermittent CTF visualization of appropriate dilution of the test contrast pocket.

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

Patient is a 59-year-old man with a large chest and shoulders (suit coat size, 46 regular) having left-sided neck pain, C7 and C8 radiculopathy.

A–C, CTF images in neutral position at C7–T1 with exposure parameters: 120 kVp/50 mA (A), 140 kVp/50 mA (B), and 140 kVp/100 mA (C).

D–F, CTF images in the swimmer's position at C7–T1 with exposure parameters: 120 kVp/50 mA (D), 140 kVp/50 mA (E), and 140 kVp/100 mA (F).

Progressive reduction in beam-hardening artifact and improved bone/tissue definition are noted in that the CTF exposure parameters in both neutral position (A–C) and swimmer's position (D–F) are increased. Reduced beam-hardening artifact and improved bone/tissue definition are present in the swimmer's position (D–F) compared with the neutral position (A–C) at the same kilovolt-pascal/milliampere exposure settings. The swimmer's position offers a greater range of approach options to the left C7–T1 foramen (F, arrow) compared with limitations presented in the neutral position (C, arrow) because of the proximity of the clavicle, lateral chest wall, and shoulder.

G, swimmer's position induces vertebral body and foramen tilt, altering visible appearance of the needle approach. The needle is seen approaching the inferior margin of the C7 transverse process tubercle and roof of the C7–T1 foramen (short arrow). C8 nerve root is seen exiting medially and inferiorly to the foramen roof (long arrow).

H, Successful C8 CNRB performed at C7–T1 (arrow) with contrast seen adjacent to the C8 root. Patient's symptoms completely resolved with the C7 and C8 injections.

Radiation Exposure with CTF

Theoretical operator/patient radiation exposure during CNRB by CTF was assessed using 2 cylindrical lucite CT phantoms (16 cm diameter [standard neck simulation], 32 cm diameter [swimmer's position simulation]). Deep patient exposure was evaluated in continuous mode with a phantom center location pencil CT ion chamber and electrometer (Radcal, Monrovia, Calif). Operator exposure was measured at 0.6 and 1.0 m in left/right lateral and center table positions during continuous mode using a micro-R ion chamber survey meter (Inovision, Cleveland, Ohio) and averaged using: 120/140 kVp and 50/100 mA with 20–25 cm FOV and 3-mm section thickness.

Results

CNRB with Swimmer's Position

All CNRBs were successful and no complications were encountered. Adequate visualization of critical structures was obtained with CTF in the swimmer's position using only minor modification of standard milliampere (mA) and kilovolt-pascal (kVp) settings because of decreased tissue mass in the CT beam. Low shoulder position increased foraminal access options that avoided the carotid artery and jugular vein (Fig 1F). CTF allowed rapid access to the neural foramen even in those patients with LBH, resulting in short CNRB procedure time. Cumulative CTF time was approximately 15–20 seconds per treated level, and technical procedure time paralleled typical CNRBs performed in the standard neutral position.

Bone/tissue clarity increased with CTF exposure in both neutral and swimmer's position (Fig 1A–F). Visualization at 140 kVp/100 mA was superior (Fig 1F) but not considered routinely necessary to identify and avoid problem structures. Image quality appeared acceptable, and artifacts were equivalent between the neutral position 140-kVp/100-mA and the swimmer's position 140-kVp/50-mA exposures (Fig 1C, -E). Moderate artifacts were still present in the neutral position at 140 kVp/50 mA (Fig 1B).

Radiation Exposure at CTF

Patient/operator exposure (Table) increased linearly with increasing milliamperes. Operator exposure was significantly greater at close (0.6 m) compared with routine exposure distance (1.0 m). Operator/patient exposure with the 32 cm phantom at 1 m was lower with 140 kVp/50 mA than with 140 kVp/100 mA or 120 kVp/100 mA.

View this table:
  • View inline
  • View popup

Radiation exposure

Discussion

Patients with large upper body habitus are challenging to image at the cervicothoracic junction. CNRB is difficult in this region because it is crucial to identify and avoid such vital structures as the carotid artery, jugular vein, and vertebral artery.

The swimmer's position, similar to the lateral decubitus position,5 can be effectively used in performing CNRB in patients with LBH with adequate structure visualization and standard root access and CTF times. Even with the swimmer's position, an increase in CTF dose is generally required for adequate structure visualization. Beam-hardening artifacts were severe in the neutral position and remained compromised in the swimmer's position at 120 kVp/50 mA (Fig 1A, -D). Surprisingly, image quality was similar between the 140 kVp/50 mA swimmer's position (Fig 1E) and 140 kVp/100 mA neutral position (Fig 1C) exposures, despite the lower dose at 140 kVp/50 mA. Visualization was markedly improved at 140 kVp/100 mA (Fig 1F) but not necessary to identify and avoid crucial structures. The operator can therefore assess/modify the available parameters, if necessary, and limit exposure. Radiation exposure studies have assessed CTF doses ranging from 10 to 100 mA at 120–140 kVp.6 In our practice, 120 kVp and 40–60 mA is standard for most uncomplicated CNRB procedures.

CNRB can also be performed with traditional fluoroscopic guidance.7–10 Advocates prefer this technique because of the continuous visualization of the steroid/contrast mixture during injection for detection of intravascular migration.11–13 With confirmation of needle tip position using anteroposterior, oblique, and lateral fluoroscopic images, a similar limitation can occur at the cervicothoracic junction in patients with LBH, particularly in the lateral and oblique positions.7–10 In addition, the fluoroscopic approach does not allow direct visualization or avoidance of the carotid artery, jugular vein, or vertebral artery and may present alternative limitations and risks.

Conclusion

CNRBs at low cervical levels can be successfully performed by CT fluoroscopy in patients with LBH using the swimmer's position to reduce scanned tissue mass and improve trajectory options. CTF parameters can be chosen to limit patient/operator exposure even in these challenging lower cervical locations.

Acknowledgments

The authors would like to thank Eric Jablonowski for his assistance in image preparation.

References

  1. ↵
    Kapoor V, Rothfus WE, Grahovac SZ, et al. Refractory occipital neuralgia: preoperative assessment with CT-guided nerve block prior to dorsal cervical rhizotomy. AJNR Am J Neuroradiol 2003;24:2105–10
    Abstract/FREE Full Text
  2. Cyteval C, Thomas E, Decoux E, et al. Cervical radiculopathy: open study on percutaneous periradicular foraminal steroid infiltration performed under CT control in 30 patients. AJNR Am J Neuroradiol 2004;25:441–45
    Abstract/FREE Full Text
  3. ↵
    Wagner AL. CT fluoroscopic-guided cervical nerve root blocks. AJNR Am J Neuroradiol 2005;26:43–44
    Abstract/FREE Full Text
  4. ↵
    Kane AG, Reilly KC, Murphy TF. Swimmer's CT: improved imaging of the lower neck and thoracic inlet. AJNR Am J Neuroradiol 2004;25:859–62
    Abstract/FREE Full Text
  5. ↵
    Fenton DS, Czervionke LF. Selective nerve root block. In: Fenton DS, Czervionke LF, eds. Image-Guided Spine Intervention. Philadelphia: Saunders;2003 :73–98
  6. ↵
    Paulson EK, Sheafor DH, Enterline DS, et al. CT fluoroscopy-guided interventional procedures: techniques and radiation dose to radiologists. Radiology 2001;220:161–67
    PubMed
  7. ↵
    Morvan G, Monpoint D, Bard M Levi-Valensin G. Direct intra-foraminal injection of corticosteroids in the treatment of cervico-brachial pain. In: Bard M, Laredo JD, eds. Interventional Radiology in Bone and Joint. New York: Springer-Verlag;1988 :253–57
  8. Bush K, Hiller S. Outcome of cervical radiculopathy treated with periradicular/epidural corticosteroid injections: a prospective study with independent clinical review. Eur Spine J 1996;5:319–25
    CrossRefPubMed
  9. Slipman CW, Lipetz JS, Jackson HB, et al. Therapeutic selective nerve root block in the nonsurgical treatment of atraumatic cervical spondylotic radicular pain: a retrospective analysis with independent clinical review. Arch Phys Med Rehabil 2000;81:741–46
    PubMed
  10. ↵
    Vallee JN, Feydy A, Carlier RY, et al. Chronic cervical radiculopathy: lateral approach periradicular corticosteroid injection. Radiology 2001;218:886–92
    PubMed
  11. ↵
    Brouwers PJAM, Kottink EJBL, Simon MAM, et al. A cervical anterior spinal artery syndrome after diagnostic blockade of the right C6-nerve root. Pain 2001;91:397–99
    CrossRefPubMed
  12. Baker R, Dreyfuss P, Mercer S, et al. Cervical transforaminal injection of corticosteroids into a radicular artery: a possible mechanism for spinal cord injury. Pain 2003;103:211–15
    CrossRefPubMed
  13. ↵
    Furman MB, Giovanniello MT, O'Brien EM. Incidence of intravascular penetration in transforaminal cervical epidural steroid injections. Spine 2003;28:21–25
    CrossRefPubMed
  • Received June 2, 2006.
  • Accepted after revision October 17, 2006.
  • Copyright © American Society of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 28 (4)
American Journal of Neuroradiology
Vol. 28, Issue 4
April 2007
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Lower Cervical Nerve Root Block Using CT Fluoroscopy in Patients with Large Body Habitus: Another Benefit of the Swimmer's Position
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
W.S. Bartynski, D.S. Whitt, M.A. Sheetz, R.B. Jennings, W.E. Rothfus
Lower Cervical Nerve Root Block Using CT Fluoroscopy in Patients with Large Body Habitus: Another Benefit of the Swimmer's Position
American Journal of Neuroradiology Apr 2007, 28 (4) 706-708;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Lower Cervical Nerve Root Block Using CT Fluoroscopy in Patients with Large Body Habitus: Another Benefit of the Swimmer's Position
W.S. Bartynski, D.S. Whitt, M.A. Sheetz, R.B. Jennings, W.E. Rothfus
American Journal of Neuroradiology Apr 2007, 28 (4) 706-708;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Technique
    • Results
    • Discussion
    • Conclusion
    • Acknowledgments
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Lateral Decubitus Positioning for Cervical Nerve Root Block Using CT Image Guidance Minimizes Effective Radiation Dose and Procedural Time
  • Selective Cervical Nerve Root Blockade: Prospective Study of Immediate and Longer Term Complications
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Dynamic CT Myelography: Patient Positioning
  • Evaluation of SIH MR Scoring Systems in Normals
  • Management Outcomes For VO Spine Biopsy
Show more SPINE IMAGING AND SPINE IMAGE-GUIDED INTERVENTIONS

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire