Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticleINTERVENTIONAL

Aneurysmal Pressure Changes with Nondetachable Balloon Placement and Fluid Infusion: Rationale for Liquid Embolization

Steven G. Imbesi, Kimberly Knox and Charles W. Kerber
American Journal of Neuroradiology May 2005, 26 (5) 1232-1236;
Steven G. Imbesi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kimberly Knox
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Charles W. Kerber
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Article Figures & Data

Figures

  • Tables
  • Fig 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    Fig 1.

    Clear, elastic, silicone replica of a lateral sidewall aneurysm.

    A, A needle is inserted through the dome, with its tip in the sac to measure intra-aneurysmal pressure. A microcatheter is positioned with its tip in the lumen of the aneurysm. A nondetachable silicone balloon placed in the parent vessel across the aneurysmal neck is inflated, with the use of dyed fluid for visualization.

    B, Infusion of dyed fluid into the aneurysm sac via the microcatheter during balloon inflation.

    C, Infused fluid exits the aneurysmal sac along a channel created by the microcatheter between the nondetachable balloon and the wall of the parent vessel; fluid collects in the lumen of the proximal parent vessel.

Tables

  • Figures
    • View popup
    TABLE 1:

    Physiologic pressure measurements in aneurysm

    BaselineBalloon InflationFluid InfusionChange
    Balloon Inflation − BaselineFluid Infusion − Balloon Inflation
    94106107121
    94107107130
    93106107131
    94106107121
    94106108122
    94106108122
    95107108121
    94106107121
    • Note.—Data are MAPs in units of millimeters of mercury

    • View popup
    TABLE 2:

    Low pressure measurements in aneurysm

    BaselineBalloon InflationFluid InfusionChange
    Balloon Inflation − BaselineFluid Infusion − Balloon Inflation
    264143152
    264041141
    264243161
    264044144
    264243161
    254142161
    264143152
    264243161
    • Note.—Data are MAPs in units of millimeters of mercury.

    • View popup
    TABLE 3:

    Low pressure measurements in aneurysm

    BaselineBalloon InflationFluid InfusionChange
    Balloon Inflation − BaselineFluid Infusion − Balloon Inflation
    264145154
    264143152
    254143162
    264143152
    264142151
    264043143
    264343170
    264243161
    • Note.—Data are MAPs in units of millimeters of mercury.

PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 26 (5)
American Journal of Neuroradiology
Vol. 26, Issue 5
1 May 2005
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Aneurysmal Pressure Changes with Nondetachable Balloon Placement and Fluid Infusion: Rationale for Liquid Embolization
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
Steven G. Imbesi, Kimberly Knox, Charles W. Kerber
Aneurysmal Pressure Changes with Nondetachable Balloon Placement and Fluid Infusion: Rationale for Liquid Embolization
American Journal of Neuroradiology May 2005, 26 (5) 1232-1236;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Aneurysmal Pressure Changes with Nondetachable Balloon Placement and Fluid Infusion: Rationale for Liquid Embolization
Steven G. Imbesi, Kimberly Knox, Charles W. Kerber
American Journal of Neuroradiology May 2005, 26 (5) 1232-1236;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Methods
    • Results
    • Discussion
    • Conclusion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • CT-Guided C2 Dorsal Root Ganglion Radiofrequency Ablation for the Treatment of Cervicogenic Headache: Case Series and Clinical Outcomes
  • Safety, Efficacy, and Durability of Stent-Assisted Coiling Treatment of M2 (Insular) Segment MCA Aneurysms
  • Endovascular Management of Intracranial Dural AVFs: Transvenous Approach
Show more INTERVENTIONAL

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire