Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Abstract

Evaluation of particulate embolic materials with MR imaging, scanning electron microscopy, and phase-contrast microscopy.

K Nakabayashi, M Negoro, T Handa, H Keino, M Takahashi and K Sugita
American Journal of Neuroradiology March 1997, 18 (3) 485-491;
K Nakabayashi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M Negoro
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T Handa
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H Keino
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M Takahashi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
K Sugita
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • PDF
Loading

Abstract

PURPOSE To analyze the properties and embolic effect of microfibrillar collagen (MFC), Gelfoam powder, and polyvinyl alcohol (PVA) materials that are used in embolization procedures in the head and neck.

METHODS The shape and surface of these embolic agents were examined with scanning electron microscopy and phase-contrast microscopy. The mean number of areas of T2-weighted high signal intensity was measured on MR images in a rat embolization model to estimate the embolic effect.

RESULTS By scanning electron microscopy and phase-contrast microscopy, MFC appears fibriform and has various sizes and an irregular surface. Gelfoam is of uniform size and has a smooth surface. PVA materials are granulated and have a rough surface. MFC is somewhat suspendable and its shape changes moderately after suspension. Gelfoam is very suspendable and its shape changes rapidly. PVA showed only mild swelling. The embolic effect of MFC was the lowest of the materials examined. Large PVA particles (250 to 500 microns) showed a lesser embolic effect than Gelfoam or small PVA particles (50 to 150 microns) or medium-sized PVA particles (150 to 250 microns). No significant differences were observed among the embolic effects of Gelfoam, small PVA particles (50 to 150 microns), and medium PVA particles (150 to 250 microns).

CONCLUSIONS MFC and large PVA particles (250 to 500 microns) should be used for embolization of vascular anatomy involving potentially dangerous anastomoses. Gelfoam, PVA particles of 150- to 250-micron diameter, and PVA particles of 50- to 150-micron diameter are adequate for embolization involving homogeneous and peripheral anatomy.

  • Copyright © American Society of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology
Vol. 18, Issue 3
1 Mar 1997
  • Table of Contents
  • Index by author
Advertisement
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Evaluation of particulate embolic materials with MR imaging, scanning electron microscopy, and phase-contrast microscopy.
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
K Nakabayashi, M Negoro, T Handa, H Keino, M Takahashi, K Sugita
Evaluation of particulate embolic materials with MR imaging, scanning electron microscopy, and phase-contrast microscopy.
American Journal of Neuroradiology Mar 1997, 18 (3) 485-491;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Evaluation of particulate embolic materials with MR imaging, scanning electron microscopy, and phase-contrast microscopy.
K Nakabayashi, M Negoro, T Handa, H Keino, M Takahashi, K Sugita
American Journal of Neuroradiology Mar 1997, 18 (3) 485-491;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • Responses
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Transarterial embolization of intractable nasal and oropharyngeal hemorrhage using liquid embolic agents
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire