Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Abstract

Intra- and paraorbital lesions: value of fat-suppression MR imaging with paramagnetic contrast enhancement.

R D Tien, P K Chu, J R Hesselink and J Szumowski
American Journal of Neuroradiology March 1991, 12 (2) 245-253;
R D Tien
Department of Radiology, Magnetic Resonance Institute, UCSD Medical Center 92103.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P K Chu
Department of Radiology, Magnetic Resonance Institute, UCSD Medical Center 92103.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J R Hesselink
Department of Radiology, Magnetic Resonance Institute, UCSD Medical Center 92103.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J Szumowski
Department of Radiology, Magnetic Resonance Institute, UCSD Medical Center 92103.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • PDF
Loading

Abstract

The orbital area of 18 individuals was examined by using a combination of fat-suppression contrast-enhanced MR imaging to determine whether contrast between fat and surrounding tissues could be improved over that obtained with conventional fat-suppression techniques alone. We used a hybrid technique combining two independent methods of fat suppression. Subjects consisted of 16 patients and two normal volunteers. Fifteen individuals received gadopentetate dimeglumine, and conventional T1-weighted, T2-weighted, and fat-suppression T1-weighted images were obtained. The fat-suppressed T1-weighted images obtained after contrast administration provided more information than did the conventional MR images. Intraorbital and paraorbital lesions could be distinguished easily from intraorbital fat that had been suppressed. Cases of chorioretinitis and optic neuritis could be confidently diagnosed only by this technique. Cases of optic nerve meningioma and mixed conal lesions also were better appreciated. Because of sharp contrast between tissue planes, this technique was helpful for detecting any intraorbital invasion from paraorbital lesions. Fat-suppression MR imaging with paramagnetic contrast enhancement can significantly improve the delineation of both normal and abnormal structures and better define lesional margins in the orbit, where large amounts of fat are present. Our results support earlier findings, and we suggest that postcontrast fat-suppressed T1-weighted imaging be used instead of conventional T1-weighted postcontrast imaging in evaluating orbital and paraorbital lesions.

  • Copyright © American Society of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology
Vol. 12, Issue 2
1 Mar 1991
  • Table of Contents
  • Index by author
Advertisement
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Intra- and paraorbital lesions: value of fat-suppression MR imaging with paramagnetic contrast enhancement.
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
R D Tien, P K Chu, J R Hesselink, J Szumowski
Intra- and paraorbital lesions: value of fat-suppression MR imaging with paramagnetic contrast enhancement.
American Journal of Neuroradiology Mar 1991, 12 (2) 245-253;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Intra- and paraorbital lesions: value of fat-suppression MR imaging with paramagnetic contrast enhancement.
R D Tien, P K Chu, J R Hesselink, J Szumowski
American Journal of Neuroradiology Mar 1991, 12 (2) 245-253;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • Responses
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Combined Fat- and Water-Suppressed MR Imaging of Orbital Tumors
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire