Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Abstract

Accuracy of single-voxel proton MR spectroscopy in distinguishing neoplastic from nonneoplastic brain lesions.

S D Rand, R Prost, V Haughton, L Mark, J Strainer, J Johansen, T A Kim, V K Chetty, W Mueller, G Meyer and H Krouwer
American Journal of Neuroradiology October 1997, 18 (9) 1695-1704;
S D Rand
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R Prost
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
V Haughton
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
L Mark
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J Strainer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J Johansen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T A Kim
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
V K Chetty
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
W Mueller
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
G Meyer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H Krouwer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • PDF
Loading

Abstract

PURPOSE To measure the accuracy of single-voxel, image-guided proton MR spectroscopy in distinguishing normal from abnormal brain tissue and neoplastic from nonneoplastic brain disease.

METHODS MR spectroscopy was performed at 0.5 T with the point-resolved spectroscopic pulse sequence and conventional postprocessing techniques. Subjects consisted of a consecutive series of patients with suspected brain neoplasms or recurrent neoplasia and 10 healthy adult volunteers. Fifty-five lesions in 53 patients with subsequently verified final diagnoses were included. Spectra were interpreted qualitatively by visual inspection by nonblinded readers (prospectively) with the benefit of prior clinical data and imaging studies, and by blinded readers (retrospectively). The nonblinded readers interpreted the spectra as diagnostic or not, and, if diagnostic, as neoplastic or nonneoplastic. The blinded readers classified the spectra as diagnostic or not, and, if diagnostic, as normal or abnormal and as neoplastic or nonneoplastic (when abnormal). The sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from blinded and nonblinded MR spectroscopy interpretations. A receiver operator characteristic (ROC) curve analysis was performed on blinded MR spectroscopy interpretations.

RESULTS The diagnostic accuracy averaged across four blinded readers in differentiating patients from control subjects was .96, while the area under the aggregate (pooled interpretations) ROC curve approached unity. Accuracy in the nonblinded and blinded discrimination of neoplastic from nonneoplastic disease was .96 and .83, respectively. The area under the aggregate ROC curve in the blinded discrimination of neoplasm from nonneoplasm was .89.

CONCLUSIONS Image-guided proton spectra obtained at 0.5 T from patients with suspected neoplasia can be distinguished from spectra in healthy control subjects, and neoplastic spectra can be distinguished from nonneoplastic spectra with a high degree of diagnostic accuracy.

  • Copyright © American Society of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology
Vol. 18, Issue 9
1 Oct 1997
  • Table of Contents
  • Index by author
Advertisement
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Accuracy of single-voxel proton MR spectroscopy in distinguishing neoplastic from nonneoplastic brain lesions.
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
S D Rand, R Prost, V Haughton, L Mark, J Strainer, J Johansen, T A Kim, V K Chetty, W Mueller, G Meyer, H Krouwer
Accuracy of single-voxel proton MR spectroscopy in distinguishing neoplastic from nonneoplastic brain lesions.
American Journal of Neuroradiology Oct 1997, 18 (9) 1695-1704;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Accuracy of single-voxel proton MR spectroscopy in distinguishing neoplastic from nonneoplastic brain lesions.
S D Rand, R Prost, V Haughton, L Mark, J Strainer, J Johansen, T A Kim, V K Chetty, W Mueller, G Meyer, H Krouwer
American Journal of Neuroradiology Oct 1997, 18 (9) 1695-1704;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • Responses
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Deletion of Crtc1 leads to hippocampal neuroenergetic impairments associated with depressive-like behavior
  • Multimodal Elucidation of Choline Metabolism in a Murine Glioma Model Using Magnetic Resonance Spectroscopy and 11C-Choline Positron Emission Tomography
  • Biologic Imaging of Head and Neck Cancer: The Present and the Future
  • Proton MR Spectroscopy Improves Discrimination between Tumor and Pseudotumoral Lesion in Solid Brain Masses
  • Use of serial proton magnetic resonance spectroscopy to differentiate low grade glioma from tumefactive plaque in a patient with multiple sclerosis
  • Proton MR Spectroscopic Evaluation of Suspicious Brain Lesions After Stereotactic Radiotherapy
  • The Choline/Creatine Ratio in Five Benign Neoplasms: Comparison with Squamous Cell Carcinoma by Use of in Vitro MR Spectroscopy
  • Discrimination between Neoplastic and Nonneoplastic Brain Lesions by Use of Proton MR Spectroscopy: The Limits of Accuracy with a Logistic Regression Model
  • Effect of Voxel Position on Single-Voxel MR Spectroscopy Findings
  • Intraventricular Meningiomas: MR Imaging and MR Spectroscopic Findings in Two
  • Classification of Biopsy-Confirmed Brain Tumors Using Single-Voxel MR Spectroscopy
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire