Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

ReplyLetter

Reply:

R. van den Berg, J.J. Schneiders, S.P. Ferns, C.B. Majoie and E. Vanbavel
American Journal of Neuroradiology March 2013, 34 (3) E33; DOI: https://doi.org/10.3174/ajnr.A3514
R. van den Berg
aDepartment of Radiology
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J.J. Schneiders
aDepartment of Radiology
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S.P. Ferns
aDepartment of Radiology
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C.B. Majoie
aDepartment of Radiology
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
E. Vanbavel
bDepartment of Biomechanical Engineering and Physics Academic Medical Center, University of Amsterdam Amsterdam, the Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

We thank Drs Wang and Yuan for their detailed mathematic analysis of our Technical Note entitled “A Flow-Diverting Stent Is Not a Pressure-Diverting Stent.” The authors indeed made a good observation that the SILK stent (Balt Extrusion, Montmorency, France) was not optimally deployed at the initial stage of the procedure. The cause of the suboptimal initial deployment was either due to the mass effect by the aneurysm or to focal vasospasm. The latter is less likely because treatment had already been performed at day 3 after presentation, but more important, the patient did not show signs of a subarachnoid hemorrhage.

The illustration (Fig 1 in the original article) indeed shows that the struts of the Silk stent are arranged at an angle indicating deployment below its nominal diameter. In such circumstances, the flow-diversion effect was probably less than at optimal (nominal) deployment. This difference might have impacted the flow-dynamic effect in that measurements with the ComboWire (Volcano Corporation, Rancho Cordova, California) were affected, and the pressure and flow reduction might have been better when optimal deployment was achieved. However, despite the drawback, we did see changes in the pressure inside the aneurysm with time (Fig 2 in the original article), with a temporary reduction in pressure inside the aneurysm but a subsequent return to baseline values 5 minutes after deployment (from t = 5 minutes to t = 10 minutes). The deployment of the stent remained stable during this interval; therefore, the alteration in the pressure curve occurred when the stent was suboptimally deployed. One might question whether intra-aneurysmal pressure would have dropped more in a situation of optimal deployment. However, this change could only have occurred if substantial leakage had existed through the aneurysm wall or via other exit pathways. In this case, simple physics dictates intra-aneurysmal pressure to be Pintra = Part·Rleak/(Raccess + Rleak), with Part, the local arterial pressure; Raccess, the access resistance through the stent; and Rleak, the resistance of the leakage pathways. A better deployment raises Raccess, but there seems very little reason to assume that it would approach the high resistance of any tiny leakage pathways, if these exist at all. Hence, we expect intra-aneurysmal pressure to be nearly equal to intra-arterial pressure, even when stent deployment is more optimal. Of relevance, on the basis of similar physics, pressure pulsations in the aneurysm are expected to be damped better if access resistance is higher or if aneurysmal compliance is higher. Alas, we did not perform any repeat measurements in other patients to confirm such physical analysis.

In addition to our own response, we also asked for the manufacturer of the Silk stent, Mr N. Plowiecki, to respond. He agreed with the analysis of the stent struts and deployment by Drs Wang and Yuan and supports their statements that the analysis of the flow-dynamic effect should be seen in relation to and as a function of the angle of the struts of the stent.

At present, we have a 3-year follow-up on the occlusion rate of the aneurysm. On a recent contrast-enhanced MR angiography study, complete occlusion of the aneurysm is seen. Moreover, the mass effect of the aneurysm has diminished. The suboptimal deployment of the Silk stent has at least not hindered the progressive occlusion of the aneurysm. The patient is in stable neurologic condition, and no hemorrhage has occurred since treatment.

  • © 2013 by American Journal of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 34 (3)
American Journal of Neuroradiology
Vol. 34, Issue 3
1 Mar 2013
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Reply:
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
R. van den Berg, J.J. Schneiders, S.P. Ferns, C.B. Majoie, E. Vanbavel
Reply:
American Journal of Neuroradiology Mar 2013, 34 (3) E33; DOI: 10.3174/ajnr.A3514

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Reply:
R. van den Berg, J.J. Schneiders, S.P. Ferns, C.B. Majoie, E. Vanbavel
American Journal of Neuroradiology Mar 2013, 34 (3) E33; DOI: 10.3174/ajnr.A3514
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • Actual Metal Coverage at the Neck Is Critical for Flow-Diverting Stents in Treating Intracranial Aneurysms
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Letter to the Editor regarding “Automated Volumetric Software in Dementia: Help or Hindrance to the Neuroradiologist?”
  • Reply:
  • Brain AVM’s Nidus: What if We Hadn’t Understood Anything?
Show more LETTERS

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire