Deep-Learning Reconstruction for 7T MP2RAGE and SPACE MRI: Improving Image Quality at High Acceleration Factors

Zeyu Liu, Vishal Patel, Xiangzhi Zhou, Shengzhen Tao, Thomas Yu, Jun Ma, Dominik Nickel, Patrick Liebig, Erin M. Westerhold, Hamed Mojahed, Vivek Gupta and Erik H. Middlebrooks

This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.

ABSTRACT

BACKGROUND AND PURPOSE: Deep learning (DL) reconstruction has been successful in realizing otherwise impracticable acceleration factors and improving image quality in conventional MRI field strengths; however, there has been limited application to ultra-high field MRI.

The objective of this study was to evaluate the performance of a prototype DL-based image reconstruction technique in 7T MRI of the brain utilizing MP2RAGE and SPACE acquisitions, in comparison to reconstructions in conventional compressed sensing (CS) and controlled aliasing in parallel imaging (CAIPIRINHA) techniques.

MATERIALS AND METHODS: This retrospective study involved 60 patients who underwent 7T brain MRI between June 2024 and October 2024, comprised of 30 patients with MP2RAGE data and 30 patients with SPACE FLAIR data. Each set of raw data was reconstructed with DL-based reconstruction and conventional reconstruction. Image quality was independently assessed by two neuroradiologists using a 5-point Likert scale, which included overall image quality, artifacts, sharpness, structural conspicuity, and noise level. Inter-observer agreement was determined using top-box analysis. Contrast-to-noise ratio (CNR) and noise levels were quantitatively evaluated and compared using the Wilcoxon signed-rank test.

RESULTS: DL-based reconstruction resulted in a significant increase in overall image quality and a reduction in subjective noise level for both MP2RAGE and SPACE FLAIR data (all P<0.001), with no significant differences in image artifacts (all P>0.05). When compared to standard reconstruction, the implementation of DL-based reconstruction yielded an increase in CNR of 49.5% [95% CI 33.0-59.0%] for MP2RAGE data and 90.6% [95% CI 73.2-117.7%] for SPACE FLAIR data, along with a decrease in noise of 33.5% [95% CI 23.0-38.0%] for MP2RAGE data and 47.5% [95% CI 41.9-52.6%] for SPACE FLAIR data.

CONCLUSIONS: DL-based reconstruction of 7T MRI significantly enhanced image quality compared to conventional reconstruction without introducing image artifacts. The achievable high acceleration factors have the potential to substantially improve image quality and resolution in 7T MRI.

ABBREVIATIONS: CAIPIRINHA = Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration; CNR = contrast-to-noise ratio; CS = compressed sensing; DL = deep learning; MNI = Montreal Neurological Institute; MP2RAGE = Magnetization-Prepared 2 Rapid Acquisition Gradient Echoes; SPACE = Sampling Perfection with Application-Optimized Contrasts using Different Flip Angle Evolutions

Footnotes

  • This work has been funded by the German Federal Ministry of Education and Research, Integrated Deep Learning at 7T -IDL@7T, 13GW0682A. E.H.M. is a paid speaker for Siemens Healthineers. T.Y., J.M., D.N., P.L., and H.M. are employees of Siemens Healthineers.

Log in through your institution