Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Review ArticleHead and Neck Imaging

High-Resolution 3D-Constructive Interference in Steady-State MR Imaging and 3D Time-of-Flight MR Angiography in Neurovascular Compression: A Comparison between 3T and 1.5T

M. Garcia, R. Naraghi, T. Zumbrunn, J. Rösch, P. Hastreiter and A. Dörfler
American Journal of Neuroradiology March 2012, DOI: https://doi.org/10.3174/ajnr.A2974
M. Garcia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R. Naraghi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T. Zumbrunn
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J. Rösch
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
P. Hastreiter
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Dörfler
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: High-resolution MR imaging is useful for diagnosis and preoperative planning in patients with NVC. Because high-field MR imaging promises higher SNR and resolution, the aim of this study was to determine the value of high-resolution 3D-CISS and 3D-TOF MRA at 3T compared with 1.5T in patients with NVC.

MATERIALS AND METHODS: Forty-seven patients with NVC, trigeminal neuralgia, hemifacial spasm, and glossopharyngeal neuralgia were examined at 1.5T and 3T, including high-resolution 3D-CISS and 3D-TOF MRA sequences. Delineation of anatomic structures, overall image quality, severity of artifacts, visibility of NVC, and assessment of the SNR and CNR were compared between field strengths.

RESULTS: SNR and CNR were significantly higher at 3T (P < .001). Significantly better anatomic conspicuity, including delineation of CNs, nerve branches, and assessment of small vessels, was obtained at 3T (P < .02). Severity of artifacts was significantly lower at 3T (P < .001). Consequently, overall image quality was significantly higher at 3T. NVC was significantly better delineated at 3T (P < .001). Six patients in whom NVC was not with certainty identifiable at 1.5T were correctly diagnosed at 3T.

CONCLUSIONS: Patients with NVC may benefit from the higher resolution and greater sensitivity of 3T for preoperative assessment of NVC, and 3T may be of particular value when 1.5T is equivocal.

Abbreviations

CISS
constructive interference in steady state
CN
cranial nerve
CNR
contrast-to-noise ratio
MIP
maximum intensity projection
MVD
microvascular decompression
NVC
neurovascular compression
REZ
root exit zone
SI
signal intensity
TOF
time-of-flight
VRT
volume-rendering technique
  • © 2012 American Society of Neuroradiology
Next
Back to top
Advertisement
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
High-Resolution 3D-Constructive Interference in Steady-State MR Imaging and 3D Time-of-Flight MR Angiography in Neurovascular Compression: A Comparison between 3T and 1.5T
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
M. Garcia, R. Naraghi, T. Zumbrunn, J. Rösch, P. Hastreiter, A. Dörfler
High-Resolution 3D-Constructive Interference in Steady-State MR Imaging and 3D Time-of-Flight MR Angiography in Neurovascular Compression: A Comparison between 3T and 1.5T
American Journal of Neuroradiology Mar 2012, DOI: 10.3174/ajnr.A2974

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
High-Resolution 3D-Constructive Interference in Steady-State MR Imaging and 3D Time-of-Flight MR Angiography in Neurovascular Compression: A Comparison between 3T and 1.5T
M. Garcia, R. Naraghi, T. Zumbrunn, J. Rösch, P. Hastreiter, A. Dörfler
American Journal of Neuroradiology Mar 2012, DOI: 10.3174/ajnr.A2974
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
  • Info & Metrics
  • Responses
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Imaging and Surgical Findings in Patients with Hemi-Laryngopharyngeal Spasm and the Potential Role of MRI in the Diagnostic Work-Up
  • Crossref (59)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • MRI of the Trigeminal Nerve in Patients With Trigeminal Neuralgia Secondary to Vascular Compression
    Marion A. Hughes, Andrew M. Frederickson, Barton F. Branstetter, Xiao Zhu, Raymond F. Sekula
    American Journal of Roentgenology 2016 206 3
  • Factors Determining the Outcome in Trigeminal Neuralgia Treated With Percutaneous Balloon Compression
    Tugrul Cem Unal, Omer Faruk Unal, Orhan Barlas, Kemal Hepgul, Achmet Ali, Aydin Aydoseli, Yavuz Aras, Pulat Akin Sabanci, Altay Sencer, Nail Izgi
    World Neurosurgery 2017 107
  • Imaging of hemifacial spasm
    M. Hermier
    Neurochirurgie 2018 64 2
  • Preoperative Evaluation of Patients with Hemifacial Spasm by Three-dimensional Time-of-Flight (3D-TOF) and Three-dimensional Constructive Interference in Steady State (3D-CISS) Sequence
    J.-m. Jia, H. Guo, W.-j. Huo, S.-w. Hu, F. He, X.-d. Sun, G.-j. Lin
    Clinical Neuroradiology 2016 26 4
  • Three-dimensional observation of Virchow–Robin spaces in the basal ganglia and white matter and their relevance to idiopathic normal pressure hydrocephalus
    Masatsune Ishikawa, Shigeki Yamada, Kazuo Yamamoto
    Fluids and Barriers of the CNS 2015 12 1
  • Role of Fused Three-Dimensional Time-of-Flight Magnetic Resonance Angiography and 3-Dimensional T2-Weighted Imaging Sequences in Neurovascular Compression
    Omneya A. Gamaleldin, Mohamed Mahmoud Donia, Nermeen A. Elsebaie, Ahmed Abdelkhalek Abdelrazek, Tarek Rayan, Mohamed Hossameldin Khalifa
    World Neurosurgery 2020 133
  • Microvascular Decompression for Trigeminal Neuralgia
    Burak Sade, Joung H. Lee
    Neurosurgery Clinics of North America 2014 25 4
  • Three-Dimensional Constructive Interference in Steady State (3D CISS) Imaging and Clinical Applications in Brain Pathology
    Marco Cavallaro, Alessandra Coglitore, Agostino Tessitore, Karol Galletta, Luciano Frosina, Antonino Cuffari, Roberta Ingrassia, Sarah Caroline Scarcella, Michele Caponnetto, Mirta Longo, Francesca Granata, Sergio Lucio Vinci, Enricomaria Mormina
    Biomedicines 2022 10 11
  • Preoperative Three-Dimensional Diagnosis of Neurovascular Relationships at the Root Exit Zones During Microvascular Decompression for Hemifacial Spasm
    Keisuke Ohtani, Toshihiro Mashiko, Keiji Oguro, Atsuhito Takemura, Toru Hatayama, Tatsuya Sasaki, Eiju Watanabe
    World Neurosurgery 2016 92
  • The Role of Preoperative Magnetic Resonance Imaging in Assessing Neurovascular Compression Before Microvascular Decompression in Trigeminal Neuralgia
    Risheng Xu, Sumil K. Nair, Divyaansh Raj, Joshua Materi, Raymond J. So, Sachin K. Gujar, Judy Huang, Ari M. Blitz, Michael Lim, Haris I. Sair, Chetan Bettegowda
    World Neurosurgery 2022 168

More in this TOC Section

  • ASL Sensitivity for Head and Neck Paraganglioma
  • Post SRS Peritumoral Hyperintense Signal of VSs
  • DIVr of NPC Predicted Outcome
Show more Head and Neck Imaging

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire