Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticleHead & Neck
Open Access

MR Imaging of the Facial Nerve through the Temporal Bone at 3T with a Noncontrast Ultrashort Echo Time Sequence

J.P. Guenette, R.T. Seethamraju, J. Jayender, C.E. Corrales and T.C. Lee
American Journal of Neuroradiology October 2018, 39 (10) 1903-1906; DOI: https://doi.org/10.3174/ajnr.A5754
J.P. Guenette
aFrom the Division of Neuroradiology (J.P.G., J.J., T.C.L.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J.P. Guenette
R.T. Seethamraju
cSiemens Medical Solutions USA, Inc. (R.T.S.), Boston, Massachusetts.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for R.T. Seethamraju
J. Jayender
aFrom the Division of Neuroradiology (J.P.G., J.J., T.C.L.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J. Jayender
C.E. Corrales
bDivision of Otolaryngology–Head and Neck Surgery (C.E.C.), Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for C.E. Corrales
T.C. Lee
aFrom the Division of Neuroradiology (J.P.G., J.J., T.C.L.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for T.C. Lee

Abstract

SUMMARY: The pointwise encoding time reduction with radial acquisition (PETRA) ultrashort echo time MR imaging sequence at 3T enables visualization of the facial nerve from the brain stem, through the temporal bone, to the stylomastoid foramen without intravenous contrast. Use of the PETRA sequence, or other ultrashort echo time sequences, should be considered in the MR imaging evaluation of certain skull base tumors and perhaps other facial nerve and temporal bone pathologies.

ABBREVIATIONS:

CNR
contrast-to-noise ratio
IR-FSPGR
inversion recovery-prepared fast spoiled gradient recalled-echo
PETRA
pointwise encoding time reduction with radial acquisition
UTE
ultrashort echo time

The cisternal, canalicular, labyrinthine, geniculate, tympanic, and mastoid segments of the facial nerve are either not detectable or only faintly visible on noncontrast T1-weighted MR images.1 Moreover, although contrast enhancement of the surrounding venous plexus can aid in facial nerve visualization, the extent of enhancement is variable and unreliable.2 We hypothesized that visibility of the facial nerve could be improved with ultrashort echo time (UTE) imaging. UTE sequences capture signal from rapidly decaying short-T2 tissue, such as cortical bone3 and middle ear ossicles4 and, therefore, should capture signal from the petrous and mastoid portions of the temporal bone. Moreover, peripheral nerves have detectable signal in the ultrashort T2 spectrum,5 so UTE imaging should provide visualization of the facial nerve. Finally, UTE imaging minimizes air-related susceptibility artifacts6 and would therefore minimize artifacts from the middle ear cavity and mastoid air cells that may contribute to nonvisualization of the facial nerve on spin-echo and gradient-echo sequences. The pointwise encoding time reduction with radial acquisition (PETRA) UTE sequence provides more consistent image quality over a wider range of conditions than similar sequences.7 This report describes the evaluation of the facial nerve segments through the temporal bone using both the default PETRA protocol and a shortened 4-minute PETRA protocol.

Materials and Methods

As part of a prospective study designed to evaluate the extracranial facial nerve, an MR imaging examination of the brain and face that included a PETRA sequence was performed in 8 healthy subjects (6 men, 2 women; 31 ± 8 years of age) between January and March 2018. All subjects provided informed consent. The study was approved by our institutional review board and performed in compliance with the Health Insurance Portability and Accountability Act.

Imaging Protocols

All imaging was performed on a Magnetom Prisma 3T MR imaging system with a 64-channel head/neck coil (Siemens, Erlangen, Germany). The default PETRA protocol as installed by Siemens (Table 1) was performed on 7 subjects and 14 facial nerves. Due to the 6-minute duration of the protocol, parameter modifications were tested to reduce imaging time while retaining the signal-to-noise ratio and contrast-to-noise ratio (CNR) of the facial nerve and surrounding structures. A modified 4-minute protocol (Table 1) was performed on 5 subjects and 10 facial nerves. Imaging with both PETRA protocols was performed on 4 subjects.

View this table:
  • View inline
  • View popup
Table 1:

Parameters for default and 4-minute PETRA sequences

Imaging Analysis

Two independent reviewers scored the visibility of the cisternal, canalicular, labyrinthine, geniculate, tympanic, and mastoid segments of the facial nerve and the greater superficial petrosal nerve on each side of each subject on all series of default PETRA and 4-minute PETRA images. One reviewer was a neuroradiologist with 10 years' attending-level experience, and 1 reviewer was a postgraduate year-5 radiology resident completing a year-long neuroradiology mini-fellowship. To allow indirect comparison with a prior study that evaluated these facial nerve segments using a 3D inversion recovery fast spoiled gradient recalled (IR-FSPGR) sequence,1 we scored the signal intensity as follows: 0, no signal; 1, faint visualization; 2, signal equivalent to that of the normal cerebellum. The scored data from both reviewers were summed and averaged for each facial nerve segment for both the default PETRA and 4-minute PETRA images. Using sample size, means, and SDs, we calculated independent-sample t tests to compare the signal intensity of the facial nerve on the 4-minute PETRA protocol images, as scored for this study, with the signal intensity of the facial nerve on the IR-FSPGR images, as scored in the study by Dehkharghani et al.1

To determine the SNR and CNR, in all 4 subjects in whom both protocols were performed, we drew ROIs on a single slice over the following structures of the default and 4-minute PETRA images: facial nerve tympanic segment, ossicle, middle ear cavity, mastoid, brain stem, and extracorporeal background region lateral to the temporal bone. The SNR and CNR were calculated as follows: SNR = Mean Signal Intensity of the Region/SD of Background Noise; CNR = SNR Region 1 − SNR Region 2.

Results

All evaluated segments of the facial nerve were visible by both reviewers (Figure) with a score of either 1 or 2 with 90.5% overall reviewer agreement. The signal intensity of all facial nerve segments was significantly greater for the 4-minute PETRA protocol images compared the IR-FSPGR images (Table 2).

FIGURE.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE.

Normal right facial nerve in a 27-year-old healthy female volunteer. Axial oblique (A and B) and sagittal oblique (C) noncontrast MR images obtained with the 4-minute PETRA protocol show the cisternal, canalicular, labyrinthine, geniculate, tympanic, and mastoid segments of the right facial nerve (white arrows) and a portion of an ossicle (black arrow). D, Sagittal oblique image obtained with the default PETRA protocol shows a slightly sharper but similar appearance to C.

View this table:
  • View inline
  • View popup
Table 2:

Signal intensity comparison of PETRA and IR-FSPGR sequences as previously reporteda

SNR and CNR values were consistently similar or higher with the 4-minute PETRA protocol compared with the default PETRA protocol (Tables 3 and 4).

View this table:
  • View inline
  • View popup
Table 3:

Signal-to-noise ratio for default and 4-minute PETRA sequences

View this table:
  • View inline
  • View popup
Table 4:

Contrast-to-noise ratio for default and 4-minute PETRA sequences

Discussion

This study demonstrates that noncontrast UTE imaging with the PETRA sequence can provide visualization of the facial nerve from the brain stem to the stylomastoid foramen. Such visualization is not possible with more routine sequences currently used in skull base or internal auditory canal imaging.1,2 The PETRA sequence is a proved alternative to an IR-FSPGR sequence in pediatric brain imaging8 and could perhaps similarly substitute for IR-FSPGR sequences in skull base imaging.

It is known that ultrashort T2 (<1 ms) MR signal can be detected in peripheral nerves and imaged. This signal originates from protons in myelin phospholipids5 and likely accounts, at least in part, for the consistent visibility of the facial nerve with the PETRA sequence. In addition, it is likely that artifacts related to the air/tissue interfaces in the temporal bone interfere with detection of signal from the facial nerve on more routine sequences. Minimization of air-related susceptibility artifacts with the UTE sequences6 may reduce such interference and may also contribute to the consistent visibility of the facial nerve with the PETRA sequence. Comparison of temporal bone imaging with multiple different UTE sequences could help elucidate the biophysical properties that allow imaging of the facial nerve through the temporal bone and help optimize the technique.

The default PETRA protocol runs nearly 6 minutes. We shortened the protocol to 4 minutes by reducing the radial acquisitions from 60,000 to 40,000. To recover SNR and CNR, we increased the first TI, which is used in the pointwise acquisition of central k-space data.6,8 Our increase of the TI from 1300 to 2000 ms would be expected to increase signal in the brain and nerve tissues at some expense to gray and white matter contrast. These parameter changes resulted in mild signal artifacts in the middle ear cavity, demonstrated by higher middle ear cavity SNR.

The major limitation of this study is that imaging was performed with a single MR imaging system on a small sample of healthy subjects and does not prove reproducibility on other MR imaging systems or in a clinical setting. In addition, the comparison of signal intensities between PETRA and IR-FSPGR sequences was made across studies performed by different researchers with different subjects and equipment.

Conclusions

A 3T MR imaging 4-minute noncontrast PETRA protocol enables visualization of the facial nerve from the brain stem, through the temporal bone, to the stylomastoid foramen. Use of the PETRA sequence, or other UTE sequences, should be considered in the MR imaging evaluation of certain skull base tumors and perhaps other facial nerve and temporal bone pathologies.

Footnotes

  • Disclosures: Jeffrey P. Guenette—RELATED: Grant: American Society of Head and Neck Radiology.* Ravi Teja Seethamraju—UNRELATED: Employment: Siemens Medical Solutions USA, Inc.; Stock/Stock Options: Siemens Medical Solutions USA, Inc. Jayender Jagadeesan—RELATED: Grant: National Institutes of Health, Comments: through the National Institute of Biomedical Imaging and Bioengineering grant number P41EB015898*; UNRELATED: Board Membership: Navigation Sciences; Consultancy: Navigation Sciences; Grants/Grants Pending: Siemens Research Grant*; Patents (Planned, Pending or Issued): system for localizing deformable tumors*; Stock/Stock Options: Navigation Sciences. Thomas C. Lee—RELATED: Grant: American Society of Head and Neck Radiology, Comments: This study was supported by the American Society of Head and Neck Radiology through the 2017 William N. Hanafee Research Grant*. *Money paid to the institution.

  • This study was supported by the American Society of Head and Neck Radiology through the 2017 William N. Hanafee Research Grant. Jagadeesan Jayender was supported by the National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, through grant number P41EB015898.

Indicates open access to non-subscribers at www.ajnr.org

References

  1. 1.
    1. Dehkharghani S,
    2. Lubarsky M,
    3. Aiken AH, et al
    . Redefining normal facial nerve enhancement: healthy subject comparison of typical enhancement patterns—unenhanced and contrast-enhanced spin-echo versus 3D inversion recovery-prepared fast spoiled gradient-echo imaging. AJR Am J Roentgenol 2014;202:1108–13 doi:10.2214/AJR.13.11659 pmid:24758667
  2. 2.
    1. Hong HS,
    2. Yi BH,
    3. Cha JG, et al
    . Enhancement pattern of the normal facial nerve at 3.0 T temporal MRI. Br J Radiol 2010;83:118–21 doi:10.1259/bjr/70067143 pmid:19546177
  3. 3.
    1. Robson MD,
    2. Gatehouse PD,
    3. Bydder M, et al
    . Magnetic resonance: an introduction to ultrashort TE (UTE) imaging. J Comput Assist Tomogr 2003;27:825–46 doi:10.1097/00004728-200311000-00001 pmid:14600447
  4. 4.
    1. Naganawa S,
    2. Nakane T,
    3. Kawai H, et al
    . Visualization of middle ear ossicles in elder subjects with ultra-short echo time MR imaging. Magn Reson Med Sci 2017;16:93–97 doi:10.2463/mrms.mp.2015-0171 pmid:27001395
  5. 5.
    1. Horch RA1,
    2. Gore JC,
    3. Does MD
    . Origins of the ultrashort-T2 1H NMR signals in myelinated nerve: a direct measure of myelin content? Magn Reson Med 2011;66:24–31 doi:10.1002/mrm.22980 pmid:21574183
  6. 6.
    1. Grodzki DM,
    2. Jakob PM,
    3. Heismann B
    . Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA). Magn Reson Med 2012;67:510–18 doi:10.1002/mrm.23017 pmid:21721039
  7. 7.
    1. Froidevaux R,
    2. Weiger M,
    3. Brunner DO, et al
    . Filling the dead-time gap in zero echo time MRI: principles compared. Magn Reson Med 2018;79:2036–45 doi:10.1002/mrm.26875 pmid:28856717
  8. 8.
    1. Aida N,
    2. Niwa T,
    3. Fujii Y, et al
    . Quiet T1-weighted pointwise encoding time reduction with radial acquisition for assessing myelination in the pediatric brain. AJNR Am J Neuroradiol 2016;37:1528–34 doi:10.3174/ajnr.A4747 pmid:27056422
  • Received April 25, 2018.
  • Accepted after revision June 3, 2018.
  • © 2018 by American Journal of Neuroradiology
Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire