Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Article CommentaryNeurointervention

Is the Risk of Balloon Assistance Underinflated?

M. Sluzewski and W.J. van Rooij
American Journal of Neuroradiology October 2008, 29 (9) 1782; DOI: https://doi.org/10.3174/ajnr.A1250
M. Sluzewski
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
W.J. van Rooij
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site

In this issue of the American Journal of Neuroradiology, Nelson et al1 make an effort to compare the incidence of complications of coiling with and without balloon assistance in a review and meta-analysis. They conclude that in the published literature to date, the use of a supportive balloon is not associated with a higher complication rate. In general, a meta-analysis should start with an unbiased systematic review that incorporates articles chosen by using predetermined inclusion criteria. If the data extracted from these studies are, to some level, homogeneous, these data can be combined by using meta-analysis.2

In a meta-analysis, the choice of inclusion criteria may determine results. What is put in is what will come out. How about the inclusion criteria in the article by Nelson et al?1 Some of their inclusion criteria can be disputed. For the most part, studies dealing exclusively with either conventional coiling only or balloon-assisted coiling only are included. A minority of included studies contain data on both techniques. However, in these “mixed articles” alone can direct comparison of complication rates be made. Most articles dealing exclusively with balloon-assisted coiling come from expert centers and may have publication bias: bad results are not likely to be published. Moreover, in most of these articles, a random study period is chosen (with possible bias) and patients are not necessarily consecutive.

Curiously, the authors use a strict inclusion criterion on reporting the frequency and outcome of thromboembolic complications and procedural ruptures as separate entities. Also, both transient and permanent complications need to be reported. As a consequence of these peculiar inclusion criteria, important articles specifically dealing with the subject with the largest patient groups3,4 are excluded because “thrombo-embolic complications and procedural ruptures and transient and permanent complications were not separately reported.”1 Surprisingly (or not?), these excluded articles happen to report the opposite of what is found by Nelson et al1: a higher complication rate with balloon assistance. Apparently, in the opinion of the authors, procedural death or disability is only of importance (and thus worth reviewing!) if the distinction between procedural rupture and thromboembolism as the cause of the complication can be made. Is there a difference between being bitten by the dog or the cat? Of course not; the only issue that matters is outcome.

The criteria used by the authors introduce an inclusion bias toward articles with just over 10 patients dealing with either assisted or unassisted coiling only and to articles either without complications or with either thrombo-embolic complications or procedural ruptures only. What would be the reason to choose the inclusion criteria in such a way that essential articles with opposite results are excluded? The publication of our study in 20063 about an increased complication rate with balloon assistance generated a number of commentaries5,6 and was subject to debate at several meetings. The neurointerventional community indicated that our complication rate exceeded reported data by far and raised questions about the methodology, aneurysm selection, and the types of balloons that were used.7 In the mean time, more recent publications have reported complication rates of balloon-assisted coiling to be in the same range as those for conventional coiling.8-11 We acknowledge that differences in complication rates with balloon assistance may exist between centers. To some extent, this can be explained by different study time frames, differences in aneurysm selection, anticoagulation regime, and more liberal or restricted use of balloon assistance. In addition, recent advancements, such as the availability of easy-to-place stents, dedicated balloons, and powerful thrombolytic drugs are likely to improve the clinical results of the treatment of difficult aneurysms.

Although we find it hard to conceive that insertion of an adjunctive balloon catheter that needs to be passed across the aneurysm neck and repeatedly occludes the parent vessel does not increase the complication rate, we encourage publication of results that are better than ours. This will stimulate meaningful and sincere discussion on the use of balloon assistance and, in time, will contribute to some form of consensus. The article of Nelson et al1 does not promote this discussion. The approach of selectively including studies that reinforce a preconceived notion should not be considered a meta-analysis.

References

  1. Shapiro M, Babb J, Becske T, et al. Safety and efficacy of adjunctive balloon remodelling during endovascular treatment of intracranial aneurysms: a literature review and meta-analysis. AJNR Am J Neuroradiol 2008;29:1777–81
  2. Pai M, McCulloch M, Gorman JD, et al. Systematic reviews and meta-analyses: an illustrated, step-by-step guide. Natl Med J India 2004;17:86–95
  3. Sluzewski M, van Rooij WJ, Beute GN, et al. Balloon-assisted coil embolization of intracranial aneurysms: incidence, complications, and angiography results. J Neurosurg 2006;105:396–99
  4. Henkes H, Fischer S, Weber W, et al. Endovascular coil occlusion of 1811 intracranial aneurysms: early angiographic and clinical results. Neurosurgery 2004;54:268–80
  5. Meyer FB. Balloon-assisted coil embolization of intracranial aneurysms J Neurosurg 2006;105:392
  6. Heros RC. Complications of balloon-assisted coil embolization of intracranial aneurysms. J Neurosurg 2006;105:393–95
  7. Bendszus M, Chapot R. Balloon-assisted coil embolization: “Surgical clip application should be considered as a first treatment option in large and wide-necked aneurysms.” J Neurosurg 2007;106:734–55, author reply 735
  8. Lubicz B, Lefranc F, Bruneau M, et al. Balloon-assisted coiling of intracranial aneurysms is not associated with a higher complication rate. Neuroradiology 2008;50:769–76 May 14. [Epub ahead of print]
  9. Layton KF, Cloft HJ, Gray LA, et al. Balloon-assisted coiling of intracranial aneurysms: evaluation of local thrombus formation and symptomatic thromboembolic complications. AJNR Am J Neuroradiol 2007;28:1172–75
  10. Ross IB, Dhillon GS. Balloon assistance as a routine adjunct to the endovascular treatment of cerebral aneurysms. Surg Neurol 2006;66:593–601
  11. White JB, Layton KF, Kallmes DF, et al. Balloon-assisted coiling through a 5-French system. Neuroradiology 2007;49:157–59

Note from Senior Editor:

A manuscript submitted to AJNR is occasionally accepted despite harsh criticism from a reviewer. In such cases, the editor may think that both the authors of the manuscript and the reviewer offer interesting points for the reader to contemplate. In the interest of allowing the reader to consider more than one opinion, AJNR will occasionally publish the article along with the reviewer's criticism, as in this case.

  • Copyright © American Society of Neuroradiology
Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire