Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

LetterLetter

Neurointerventional Guide Sheath

U.S. Kanamalla and J.P. Kochan
American Journal of Neuroradiology May 2006, 27 (5) 951;
U.S. Kanamalla
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J.P. Kochan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site

We read with interest Luzardo et al’s 1 technical note in the December issue of the AJNR. Although we are pleased that the new Envoy 6F guide catheter (Cordis, Miami Lakes, Fla) facilitated a dual-microcatheter procedure with a single arterial access, it should be noted that this is by no means a new technique. The 6F Envoy guide catheter with an inner diameter of 0.070 inches and outer diameter of 2.0 mm is comparatively new, but we have been using the same approach to perform balloon-assisted coiling with a 5F Shuttle guide sheath (Shuttle-SL; Cook, Bloomington, Ind) for more than 4 years. The 5F Shuttle guide sheath is currently our preferred guide sheath for endovascular management of intracranial aneurysms. The 5F Shuttle guide sheath has an inner diameter of 0.074 inches and an outer diameter of 0.090 inches (2.3 mm). For the purpose of balloon-assisted coil embolization, one could easily pass a compliant balloon catheter such as the HyperForm or HyperGlide (Micro Therapeutics, Irvine, Calif) and a standard 0.010- or 0.014-inch microcatheter through the Shuttle. We have used this method for other dual-catheter techniques (eg, temporary proximal balloon occlusion with nondetachable balloon catheters and coaxial coil and foreign body retrieval with the Goose Neck Snare [Microvena, Vadnais Heights, Minn] or the Retriever device [Target Therapeutics/Boston Scientific, Fremont, Calif]).

The Shuttle guide sheath is a hydrophilic-coated braided sheath that provides excellent stability during the procedures. It has a soft, radiopaque tip and is kink resistant. Cook’s Shuttle sheaths have 2 inner dilators with the 5F system (0.018 or 0.038 inch), which allows for a better transition between the wire, inner dilator, and sheath. It also comes with a side port, which facilitates contrast injection. In addition, a Tuohy rotating hemostatic valve can be connected to the side port, through which one could pass the Micro Therapeutics balloon catheter facilitating individual control of each microcatheter. Because our patients typically receive anticoagulants, on completion of the procedure we exchange the 5F Shuttle guide sheath for a standard 5F femoral arterial access sheath, which remains sutured in place overnight. We would also like to point out that, at the end of the procedure, the hole in the femoral artery is 5F when a Shuttle is used as opposed to 6F when the Envoy guiding catheter is used. As mentioned in the article, we agree that the use of this technique has resulted in reduced periprocedural risk when compared with separate femoral arterial catheterizations. We have experienced no technical complications with the use of the 5F Shuttle in conjunction with 2 microcatheters.

Reference

  1. Luzardo GD, Ross IB, Gal G. Balloon-assisted coiling through a single 6F guiding catheter. AJNR Am J Neuroradiol 2006;27:190–91
  • Copyright © American Society of Neuroradiology
Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire