Index by author
Fan, G.
- SpineOpen AccessDeep Learning–Based Automatic Segmentation of Lumbosacral Nerves on CT for Spinal Intervention: A Translational StudyG. Fan, H. Liu, Z. Wu, Y. Li, C. Feng, D. Wang, J. Luo, W.M. Wells and S. HeAmerican Journal of Neuroradiology June 2019, 40 (6) 1074-1081; DOI: https://doi.org/10.3174/ajnr.A6070
Fatterpekar, G.M.
- Head & NeckYou have accessDynamic Contrast-Enhanced MRI to Differentiate Parotid Neoplasms Using Golden-Angle Radial Sparse Parallel ImagingJ.L. Mogen, K.T. Block, N.K. Bansal, J.T. Patrie, S. Mukherjee, E. Zan, M. Hagiwara, G.M. Fatterpekar and S.H. PatelAmerican Journal of Neuroradiology June 2019, 40 (6) 1029-1036; DOI: https://doi.org/10.3174/ajnr.A6055
Feng, C.
- SpineOpen AccessDeep Learning–Based Automatic Segmentation of Lumbosacral Nerves on CT for Spinal Intervention: A Translational StudyG. Fan, H. Liu, Z. Wu, Y. Li, C. Feng, D. Wang, J. Luo, W.M. Wells and S. HeAmerican Journal of Neuroradiology June 2019, 40 (6) 1074-1081; DOI: https://doi.org/10.3174/ajnr.A6070
Fischer, N.
- FELLOWS' JOURNAL CLUBHead & NeckYou have accessReadout-Segmented Echo-Planar DWI for the Detection of Cholesteatomas: Correlation with Surgical ValidationN. Fischer, V.H. Schartinger, D. Dejaco, J. Schmutzhard, H. Riechelmann, M. Plaikner and B. HenningerAmerican Journal of Neuroradiology June 2019, 40 (6) 1055-1059; DOI: https://doi.org/10.3174/ajnr.A6079
Readout-segmented echo-planar (RESOLVE)-DWI is a new alternative technique for obtaining DWI with high quality, delivering sharp images at high spatial resolution and reduced slice thickness. Fifty patients with chronic otitis media who underwent MR imaging before an operation of the middle ear were included. The MR imaging protocol consisted of axial and coronal readout-segmented echo-planar DWI with b-values of 0 and 1000 s/mm2 and 3-mm slice thickness. The readout segmented echo-planar diffusion-weighted images were fused with standard T2-weighted sequences for better anatomic assignment. Readout-segmented echo-planar DWI detected 22 of the 25 cases of surgically proved cholesteatoma. It has an accuracy of 92%, a sensitivity of 88%, a specificity of 96%, a positive predictive value of 96%, and a negativepredictive value of 89%. Readout-segmented echo-planar DWI is a promising and reliable MR imaging sequence for the detection and exclusion of cholesteatoma.
Flemming, K.D.
- Adult BrainOpen AccessBaseline and Evolutionary Radiologic Features in Sporadic, Hemorrhagic Brain Cavernous MalformationsK.D. Flemming, S. Kumar, G. Lanzino and W. BrinjikjiAmerican Journal of Neuroradiology June 2019, 40 (6) 967-972; DOI: https://doi.org/10.3174/ajnr.A6076
Fujii, H.
- Head & NeckYou have accessLocalization of Parotid Gland Tumors in Relation to the Intraparotid Facial Nerve on 3D Double-Echo Steady-State with Water Excitation SequenceH. Fujii, A. Fujita, H. Kanazawa, E. Sung, O. Sakai and H. SugimotoAmerican Journal of Neuroradiology June 2019, 40 (6) 1037-1042; DOI: https://doi.org/10.3174/ajnr.A6078
Fujita, A.
- Head & NeckYou have accessLocalization of Parotid Gland Tumors in Relation to the Intraparotid Facial Nerve on 3D Double-Echo Steady-State with Water Excitation SequenceH. Fujii, A. Fujita, H. Kanazawa, E. Sung, O. Sakai and H. SugimotoAmerican Journal of Neuroradiology June 2019, 40 (6) 1037-1042; DOI: https://doi.org/10.3174/ajnr.A6078