Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticleNeurointervention

In Vivo Evaluation of the Phenox CRC Mechanical Thrombectomy Device in a Swine Model of Acute Vessel Occlusion

P. Mordasini, M. Hiller, C. Brekenfeld, G. Schroth, U. Fischer, J. Slotboom, M. Arnold and J. Gralla
American Journal of Neuroradiology May 2010, 31 (5) 972-978; DOI: https://doi.org/10.3174/ajnr.A1928
P. Mordasini
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Hiller
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
C. Brekenfeld
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
G. Schroth
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
U. Fischer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J. Slotboom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Arnold
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J. Gralla
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: Mechanical thrombectomy in ischemic stroke is of increasing interest as it is a promising strategy for fast and efficient recanalization. Several thrombectomy devices have been introduced to the armentarium of mechanical thrombectomy. Currently, new devices are under development and are continuously added to the neurointerventional tool box. Each device advocated so far has a different design and mechanical properties in terms of thrombus-device interaction. Therefore, a systematic evaluation under standardized conditions in vivo of these new devices is needed. The purpose of this study was to evaluate the efficiency, thrombus-device interaction, and potential complications of the novel Phenox CRC for distal mechanical thrombectomy in vivo.

MATERIALS AND METHODS: The device was evaluated in an established animal model in the swine. Recanalization rate, thromboembolic events, vasospasm, and complications were assessed. Radiopaque thrombi (2 cm length) were used for the visualization of thrombus-device interaction during retrieval. The Phenox CRC (4 mm diameter) was assessed in 15 vessel occlusions. For every occlusion a maximum of 3 retrieval attempts were performed.

RESULTS: Complete recanalization (TICI 3/TIMI 3) was achieved in 86.7% of vessel occlusions. In 66.7% (10/15), the first retrieval attempt was successful, and in 20% (3/15), the second attempt led to complete recanalization of the parent artery. In 2 cases (13.3%) thrombus retrieval was not successful (TICI 0/TIMI 0). In 1 case (6.7%) a minor embolic event occurred in a small side branch. No distal thromboembolic event was observed during the study. Thrombus-device interaction illustrated the entrapment of the thrombus by the microfilaments and the proximal cage of the device. No significant thrombus compression was observed. No vessel perforation, dissection, or fracture of the device occurred.

CONCLUSIONS: In this small animal study, the Phenox CRC was a safe and effective device for mechanical thrombectomy. The unique design with a combination of microfilaments and proximal cage reduces thrombus compression with a consequently high recanalization and low complication rate.

Abbreviations

CRC
clot retriever cage
pCR
Phenox clot retriever
TICI
Thrombolysis in Cerebral Infarction
TIMI
Thrombolysis in Myocardial Infarction
  • Copyright © American Society of Neuroradiology
View Full Text
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 31 (5)
American Journal of Neuroradiology
Vol. 31, Issue 5
1 May 2010
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
In Vivo Evaluation of the Phenox CRC Mechanical Thrombectomy Device in a Swine Model of Acute Vessel Occlusion
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
P. Mordasini, M. Hiller, C. Brekenfeld, G. Schroth, U. Fischer, J. Slotboom, M. Arnold, J. Gralla
In Vivo Evaluation of the Phenox CRC Mechanical Thrombectomy Device in a Swine Model of Acute Vessel Occlusion
American Journal of Neuroradiology May 2010, 31 (5) 972-978; DOI: 10.3174/ajnr.A1928

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
In Vivo Evaluation of the Phenox CRC Mechanical Thrombectomy Device in a Swine Model of Acute Vessel Occlusion
P. Mordasini, M. Hiller, C. Brekenfeld, G. Schroth, U. Fischer, J. Slotboom, M. Arnold, J. Gralla
American Journal of Neuroradiology May 2010, 31 (5) 972-978; DOI: 10.3174/ajnr.A1928
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • Abbreviations
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Institutional and provider variations for mechanical thrombectomy in the treatment of acute ischemic stroke: a survey analysis
  • Histological examination of vascular damage caused by stent retriever thrombectomy devices
  • Histopathologic Evaluation of Arterial Wall Response to 5 Neurovascular Mechanical Thrombectomy Devices in a Swine Model
  • What Is Meant by "TICI"?
  • Experimental Evaluation of Immediate Recanalization Effect and Recanalization Efficacy of a New Thrombus Retriever for Acute Stroke Treatment In Vivo
  • Past, present, and future of endovascular stroke therapies
  • In Vivo Evaluation of the First Dedicated Combined Flow-Restoration and Mechanical Thrombectomy Device in a Swine Model of Acute Vessel Occlusion
  • Crossref (23)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Reperfusion therapy in acute ischemic stroke: dawn of a new era?
    Sonu Bhaskar, Peter Stanwell, Dennis Cordato, John Attia, Christopher Levi
    BMC Neurology 2018 18 1
  • What Is Meant by “TICI”?
    J.E. Fugate, A.M. Klunder, D.F. Kallmes
    American Journal of Neuroradiology 2013 34 9
  • Histological examination of vascular damage caused by stent retriever thrombectomy devices
    Daisuke Arai, Akira Ishii, Hideo Chihara, Hiroyuki Ikeda, Susumu Miyamoto
    Journal of NeuroInterventional Surgery 2016 8 10
  • Histopathologic Evaluation of Arterial Wall Response to 5 Neurovascular Mechanical Thrombectomy Devices in a Swine Model
    B. Gory, D. Bresson, I. Kessler, M.L. Perrin, A. Guillaudeau, K. Durand, S. Ponsonnard, C. Couquet, C. Yardin, C. Mounayer
    American Journal of Neuroradiology 2013 34 11
  • In Vivo Evaluation of the First Dedicated Combined Flow-Restoration and Mechanical Thrombectomy Device in a Swine Model of Acute Vessel Occlusion
    P. Mordasini, N. Frabetti, J. Gralla, G. Schroth, U. Fischer, M. Arnold, C. Brekenfeld
    American Journal of Neuroradiology 2011 32 2
  • Mechanical Thrombectomy: Emerging Technologies and Techniques
    Edgar A. Samaniego, Jorge A Roa, Kaustubh Limaye, Harold P. Adams
    Journal of Stroke and Cerebrovascular Diseases 2018 27 10
  • Experimental Evaluation of Immediate Recanalization Effect and Recanalization Efficacy of a New Thrombus Retriever for Acute Stroke Treatment In Vivo
    P. Mordasini, C. Brekenfeld, J.V. Byrne, U. Fischer, M. Arnold, S. Jung, G. Schroth, J. Gralla
    American Journal of Neuroradiology 2013 34 1
  • Imaging Clot Characteristics in Stroke and its Possible Implication on Treatment
    Ana Siri Luthman, Laurie Bouchez, Daniele Botta, Maria Isabel Vargas, Paolo Machi, Karl-Olof Lövblad
    Clinical Neuroradiology 2020 30 1
  • Institutional and provider variations for mechanical thrombectomy in the treatment of acute ischemic stroke: a survey analysis
    Tapan Mehta, Shailesh Male, Coridon Quinn, David F Kallmes, Adnan H Siddiqui, Aquilla Turk, Andrew Walker Grande, Ramachandra Prasad Tummala, Bharathi Dasan Jagadeesan
    Journal of NeuroInterventional Surgery 2019 11 9
  • Past, present, and future of endovascular stroke therapies
    M.A. Taqi, N. Vora, R.C. Callison, R. Lin, T.J. Wolfe
    Neurology 2012 79 13_supplement_1

More in this TOC Section

  • Effect of SARS-CoV2 on Endovascular Thrombectomy
  • Neuroform Atlas Stent for Intracranial Aneurysms
  • Transophthalmic Artery Embolization of Meningiomas
Show more NEUROINTERVENTION

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire