Table 3:

Recommended imaging sequences for baseline imaging and ARIA monitoring examinations based on clinical trial experience and current guidelinesa

MinimalRecommendedNotes
Field strength1.5T3TUse of a consistent field strength for serial imaging of a given patient is important; imaging may be performed at 1.5T if a patient is not a candidate for imaging at 3T or 3T scanners are not available at a site
ARIA-E detection2D-FLAIR2D- or 3D-FLAIREither 2D or 3D is acceptable, whichever can be performed with consistent quality and optimal CSF suppression
ARIA-H detectionT2*-GRET2*-GRE (±SWI)Recommendations for enrollment and dose suspension are based on T2*-GRE detection of blood products; SWI may also be performed for confirmation and may be of value to gather data going forward
Infarct assessmentDWIDWIDWI required to differentiate ARIA from acute/subsacute infarct and identification of incidental infarcts
  • a Additional optional sequences may be added per individual site preference.