Change in UIA morphology measurements in relation to continuous UIA 2D and 3D growtha
Change in | Median (IQR) | Correlation Coefficient (P Value) | ||
---|---|---|---|---|
2D Growth, Length | 2D Growth, Width | 3D Growth, Volume | ||
Volume (mm3) | 1.60 (−3.70−10.80) | 0.29 (<.01)b | 0.28 (<.01)b | − |
Area (mm2) | 2.30 (−6.10−11.40) | 0.25 (<.01)b | 0.34 (<.01)b | 0.90 (<.01)b |
Compactness 1 | 0.50 (−1.70−2.60)c | 0.10 (.28) | −0.01 (.89) | 0.15 (.09) |
Compactness 2 | 0.01 (−0.04−0.07) | 0.09 (.30) | −0.02 (.86) | 0.15 (.10) |
Elongation | 0.01 (−0.03−0.04) | 0.01 (.89) | 0.02 (.79) | 0.09 (.33) |
Flatness | 0.00 (−0.03−0.04) | 0.00 (.97) | 0.05 (.58) | 0.19 (.03)b |
Sphericity | 0.01 (−0.02−0.04) | 0.10 (.27) | −0.01 (.94) | 0.15 (.09) |
Shape index | 0.00 (−0.03−0.01) | −0.09 (.32) | −0.17 (.06) | −0.33 (<.01)b |