Table 1:

Dynamic gadolinium MRI technique for imaging of the TMJ

ParametersDetails
SequenceCoronal T1 postgadolinium, 70-sec, 10-sec prescan
TR/TE (ms)400/15
Frequency × phase300 × 200
NEX1
Section thickness3 mm, 0-mm gap
FOV14–16 cm
Timing of the serial runsRuns: run 0, pregadolinium run, followed by 10 postgadolinium runs with the following timing intervals: run 1: 0 -1 min 10 sec, run 2: 1 min 20 sec to 2 min 30 sec; run 3: 2 min 40 sec to 3 min 50 sec; run 4: 4 min 00 sec to 5 min 10 sec; run 5: 5 min 20 sec to 6 min 30 sec; run 6: 6 min 40 sec to 7 min 50 sec; run 7: 8 min 00 sec to 9 min 10 sec; run 8: 9 min 20 sec to 10 min 30 sec; run 9: 10 min 40 sec to 11 min 50 sec; run 10: 12 min 00 sec to 13 min 10 sec
Injection techniqueStandard supine position
22-ga angiocatheter in right antecubital fossa, attached to 20-cm length of standard tubing connected to a power injector
Contrast agent and dosingGadoterate meglumine (Dotarem)a maintained at room temperature was drawn up at a dose of 0.2 mL/kg (0.1 mmol/kg) of body weight
Simultaneous with the start of the first coronal T1 dynamic sequence, run 1, gadoterate was administered by power injector as a single intravenous bolus injection at a flow rate of 2.5 mL/s followed by a 20-mL saline chaser at the same injection rate
  • a Guerbet, Aulnay-sous-Bois, France.