Table 2:

ADC skewness threshold obtained from ROC curve analysis to predict local failure

ParameterADC Skewness
Threshold≤0.55
P value.0001
Area under the ROC curve0.68
True-positive21
False-positive49
True-negative82
False-negative6
Sensitivity78%
Specificity63%
Accuracy65%
Positive predictive value30%
Negative predictive value93%