Pair-wise comparisons of sensitivity and specificity of MRA techniques
MRA Technique | P Value Comparing Sensitivities | P Value Comparing Specificities |
---|---|---|
Aneurysm class: 1 vs 2 ,3, 4 (for any remnant) | ||
1.5 TOF vs 1.5 CE | .3173 | .1797 |
1.5 TOF vs 3 TOF | .3173 | 1 |
1.5 TOF vs 3 CE | 1 | .2568 |
1.5 CE vs 3 TOF | .3173 | .1797 |
1.5 CE vs 3 CE | .4142 | 1 |
3 TOF vs 3 CE | 1 | 1 |
Aneurysm class: 1, 2 vs 3, 4 (for larger remnants) | ||
1.5 TOF vs 1.5 CE | .0455 | 1 |
1.5 TOF vs 3 TOF | 1 | 1 |
1.5 TOF vs 3 CE | .0455 | .5637 |
1.5 CE vs 3 TOF | .1025 | 1 |
1.5 CE vs 3 CE | 1 | .5637 |
3 TOF vs 3 CE | 1 | 1 |
Aneurysm occlusion: better or same vs worse | ||
1.5 TOF vs 1.5 CE | 1 | .6547 |
1.5 TOF vs 3 TOF | .3173 | .3173 |
1.5 TOF vs 3 CE | .1573 | .5637 |
1.5 CE vs 3 TOF | .3173 | .5637 |
1.5 CE vs 3 CE | .1573 | 1 |
3 TOF vs 3 CE | .3173 | .5637 |