PT - JOURNAL ARTICLE AU - Caroff, J. AU - Popescu, S.D. AU - Mihalea, C. AU - Popica, D.A. AU - Ikka, L. AU - Gallas, S. AU - Ozanne, A. AU - Chalumeau, V. AU - Moret, J. AU - Cortese, J. AU - Spelle, L. TI - Persistent Opacification of the Woven EndoBridge Device: A Conebeam CT Analysis of the Bicêtre Occlusion Scale Score 1 Phenomenon AID - 10.3174/ajnr.A7783 DP - 2023 Feb 09 TA - American Journal of Neuroradiology 4099 - http://www.ajnr.org/content/early/2023/02/09/ajnr.A7783.short 4100 - http://www.ajnr.org/content/early/2023/02/09/ajnr.A7783.full AB - BACKGROUND AND PURPOSE: Some Woven EndoBridge devices present a persistent intradevice opacification at imaging follow-up, described as the Bicêtre Occlusion Scale Score 1 (BOSS 1) phenomenon. The clinical implications remain unknown. We aimed here to analyze the factors influencing this occurrence and to precisely describe the evolution of BOSS 1 with time using conebeam CT.MATERIALS AND METHODS: We retrospectively analyzed a prospectively maintained Woven EndoBridge database at our tertiary center and included all patients with isolated BOSS 1 and BOSS 1 associated with small neck remnant (BOSS 1 + 2).RESULTS: Two hundred sixty-seven aneurysms were treated with a Woven EndoBridge device between July 2012 and December 2021. Follow-up with DSA was available for 220 aneurysms (median, 5 months), among which BOSS 1 and 1 + 2 were found in 9.1% (20/220) (95% CI, 5.5%—12.7%). A second DSA follow-up (median, 17 months) was performed in 15 of these 20 aneurysms, which revealed that 40% had evolved to complete Woven EndoBridge occlusion, 33% showed a decreased persistent opacification, and 27% remained stable. BOSS 1 was significantly associated with postoperative antiplatelet medication, a lower aneurysm aspect ratio, and the use of the Woven EndoBridge 17 (P < .05). The average Woven EndoBridge shape modification was less pronounced in the BOSS 1 population (P < .02). None of the BOSS 1 or 1 + 2 aneurysms required retreatment or were associated with hemorrhage occurrence.CONCLUSIONS: Isolated persistent flow inside the Woven EndoBridge device at follow-up is rare and notably associated with antiplatelet prescription. It seems to present a benign course in most cases.BOSS 1Bicêtre Occlusion Scale Score 1CBCTconebeam CTFUfollow-upWShMWEB shape modificationWEBWoven EndoBridge